Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Updated computational performance evaluation of ICRP mesh-type reference computational phantoms using PHITS, Geant4, MCNP6.3, and EGSnrc

Full metadata record
DC Field Value Language
dc.contributor.authorShin, Bangho-
dc.contributor.authorKim, Suhyeon-
dc.contributor.authorChoi, Chansoo-
dc.contributor.authorKim, Hyeonil-
dc.contributor.authorYeom, Yeon Soo-
dc.contributor.authorLee, Junyoung-
dc.contributor.authorTownson, Reid W.-
dc.contributor.authorKim, Chan Hyeong-
dc.date.accessioned2026-06-15T06:35:02Z-
dc.date.available2026-06-15T06:35:02Z-
dc.date.issued2026-06-
dc.identifier.issn0952-4746-
dc.identifier.issn1361-6498-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/213269-
dc.description.abstractThe International Commission on Radiological Protection (ICRP) has adopted mesh-type reference computational phantoms (MRCPs) for the calculation of new reference dose coefficients following the forthcoming general recommendations. In the present study, the computational performance of adult and pediatric MRCPs was systematically evaluated using recently updated Monte Carlo radiation transport codes, including PHITS (version 3.31), Geant4 (version 11.01.p02), MCNP6.3, and EGSnrc (version 2025a). Performance evaluation included initialisation time, memory usage, computation time, and multi-threading efficiency for photon, electron, and neutron transport under selected external exposure scenarios. Among the evaluated codes, EGSnrc exhibited the longest initialisation time, approximately 8-9 times longer than PHITS. Nevertheless, the absolute time remained within a few minutes. In terms of memory usage, PHITS and EGSnrc required the least memory (<2 GB), whereas Geant4 required the largest memory (approximately 13-14 GB). For computation time, EGSnrc showed the fastest performance for photons and electrons with energies <= 10 MeV, while PHITS demonstrated the shortest computation time for neutrons. MCNP6.3 consistently exhibited longer computation times compared with the other codes. When compared with simulations using the existing ICRP voxel-type reference computational phantoms (VRCPs), PHITS and Geant4 showed comparable or shorter computation times for mesh phantoms. EGSnrc exhibited comparable or shorter computation times for pediatric mesh phantoms, whereas the opposite trend was observed for adult phantoms. In contrast, MCNP6.3 consistently showed longer computation times for the MRCPs than for the VRCPs. Despite its relatively longer absolute computation time, MCNP6.3 demonstrated the best multi-threading performance among the evaluated codes, showing near-linear scaling of computation speed with increasing number of threads. The results of this study provide practical guidance for users in selecting an optimal Monte Carlo code for dose calculations using ICRP MRCPs.-
dc.format.extent14-
dc.language영어-
dc.language.isoENG-
dc.publisherIOP Publishing Ltd-
dc.titleUpdated computational performance evaluation of ICRP mesh-type reference computational phantoms using PHITS, Geant4, MCNP6.3, and EGSnrc-
dc.typeArticle-
dc.publisher.location영국-
dc.identifier.doi10.1088/1361-6498/ae670c-
dc.identifier.scopusid2-s2.0-105039976312-
dc.identifier.wosid001777452600001-
dc.identifier.bibliographicCitationJOURNAL OF RADIOLOGICAL PROTECTION, v.46, no.2, pp 1 - 14-
dc.citation.titleJOURNAL OF RADIOLOGICAL PROTECTION-
dc.citation.volume46-
dc.citation.number2-
dc.citation.startPage1-
dc.citation.endPage14-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEnvironmental Sciences & Ecology-
dc.relation.journalResearchAreaPublic, Environmental & Occupational Health-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryEnvironmental Sciences-
dc.relation.journalWebOfScienceCategoryPublic, Environmental & Occupational Health-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordAuthorICRP mesh-type reference computational phantoms-
dc.subject.keywordAuthortetrahedral mesh-
dc.subject.keywordAuthorunstructured mesh-
dc.subject.keywordAuthorMonte Carlo-
dc.subject.keywordAuthorcomputation speed-
dc.subject.keywordAuthormemory usage-
dc.subject.keywordAuthormulti-threading-
dc.identifier.urlhttps://iopscience.iop.org/article/10.1088/1361-6498/ae670c-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more