Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

약패널존이 적용된 WUF-W 접합부를 갖는 모멘트 골조의 내진 성능 평가

Full metadata record
DC Field Value Language
dc.contributor.authorHwang, Guem Taek-
dc.contributor.authorCho, Eunseon-
dc.contributor.authorHong, Minguk-
dc.contributor.authorHan, Sang Whan-
dc.date.accessioned2026-06-17T01:30:42Z-
dc.date.available2026-06-17T01:30:42Z-
dc.date.issued2025-11-
dc.identifier.issn1226-525X-
dc.identifier.issn2234-1099-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/213311-
dc.description.abstractCurrent seismic design provisions prohibit the use of a weak panel zone from using special moment frame (SMF) connections due to concerns that large deformations in these zones may lead to brittle connection failures. However, several experimental studies have demonstrated that moment connections with weak panel zones can exhibit adequate ductility and energy dissipation capacity for SMF connections. This study aims to investigate the impact of weak panel zones on the seismic performance of SMFs utilizing welded unreinforced flange-welded web (WUF-W) connections, as outlined in AISC 358-22. The analysis will consider both four-story and twelve-story SMFs. Each frame will be modeled with either strong or weak panel zones. The findings indicate that SMFs with weak panel zones demonstrate greater ductility and collapse strength compared to their counterparts with strong panel zones.-
dc.format.extent8-
dc.language한국어-
dc.language.isoKOR-
dc.publisherEarthquake Engineering Society of Korea-
dc.title약패널존이 적용된 WUF-W 접합부를 갖는 모멘트 골조의 내진 성능 평가-
dc.title.alternativeSeismic Performance Evaluation of Moment-Resisting Frames Having WUF-W Connections With Weak Panel Zones-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.5000/EESK.2025.29.6.333-
dc.identifier.scopusid2-s2.0-105040521658-
dc.identifier.bibliographicCitationJournal of the Earthquake Engineering Society of Korea, v.29, no.6, pp 333 - 340-
dc.citation.titleJournal of the Earthquake Engineering Society of Korea-
dc.citation.volume29-
dc.citation.number6-
dc.citation.startPage333-
dc.citation.endPage340-
dc.type.docTypeArticle-
dc.identifier.kciidART003258595-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorNonlinear analysis-
dc.subject.keywordAuthorSeismic performance evaluation-
dc.subject.keywordAuthorSteel moment frame-
dc.subject.keywordAuthorWeak panel zone-
dc.subject.keywordAuthorWUF-W connection-
dc.identifier.urlhttp://www.eesk-j.or.kr/journal/article.php?code=95676-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 건축공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Han, Sang Whan photo

Han, Sang Whan
COLLEGE OF ENGINEERING (SCHOOL OF ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE