Cited 340 time in
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Koh, Ahyeon | - |
| dc.contributor.author | Kang, Daeshik | - |
| dc.contributor.author | Xue, Yeguang | - |
| dc.contributor.author | Lee, Seungmin | - |
| dc.contributor.author | Pielak, Rafal M. | - |
| dc.contributor.author | Kim, Jeonghyun | - |
| dc.contributor.author | Hwang, Taehwan | - |
| dc.contributor.author | Min, Seunghwan | - |
| dc.contributor.author | Banks, Anthony | - |
| dc.contributor.author | Bastien, Philippe | - |
| dc.contributor.author | Manco, Megan C. | - |
| dc.contributor.author | Wang, Liang | - |
| dc.contributor.author | Ammann, Kaitlyn R. | - |
| dc.contributor.author | Jang, Kyung-In | - |
| dc.contributor.author | Won, Phillip | - |
| dc.contributor.author | Han, Seungyong | - |
| dc.contributor.author | Ghaffari, Roozbeh | - |
| dc.contributor.author | Paik, Ungyu | - |
| dc.contributor.author | Slepian, Marvin J. | - |
| dc.contributor.author | Balooch, Guive | - |
| dc.contributor.author | Huang, Yonggang | - |
| dc.contributor.author | Rogers, John A. | - |
| dc.date.accessioned | 2021-08-02T15:56:10Z | - |
| dc.date.available | 2021-08-02T15:56:10Z | - |
| dc.date.issued | 2016-11 | - |
| dc.identifier.issn | 1946-6234 | - |
| dc.identifier.issn | 1946-6242 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/21435 | - |
| dc.description.abstract | Capabilities in health monitoring enabled by capture and quantitative chemical analysis of sweat could complement, or potentially obviate the need for, approaches based on sporadic assessment of blood samples. Established sweat monitoring technologies use simple fabric swatches and are limited to basic analysis in controlled laboratory or hospital settings. We present a collection of materials and device designs for soft, flexible, and stretchable microfluidic systems, including embodiments that integrate wireless communication electronics, which can intimately and robustly bond to the surface of the skin without chemical and mechanical irritation. This integration defines access points for a small set of sweat glands such that perspiration spontaneously initiates routing of sweat through a microfluidic network and set of reservoirs. Embedded chemical analyses respond in colorimetric fashion to markers such as chloride and hydronium ions, glucose, and lactate. Wireless interfaces to digital image capture hardware serve as a means for quantitation. Human studies demonstrated the functionality of this microfluidic device during fitness cycling in a controlled environment and during long-distance bicycle racing in arid, outdoor conditions. The results include quantitative values for sweat rate, total sweat loss, pH, and concentration of chloride and lactate. | - |
| dc.format.extent | 13 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | American Association for the Advancement of Science | - |
| dc.title | A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1126/scitranslmed.aaf2593 | - |
| dc.identifier.scopusid | 2-s2.0-84997771406 | - |
| dc.identifier.wosid | 000389449400005 | - |
| dc.identifier.bibliographicCitation | Science Translational Medicine, v.8, no.366, pp 1 - 13 | - |
| dc.citation.title | Science Translational Medicine | - |
| dc.citation.volume | 8 | - |
| dc.citation.number | 366 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 13 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Cell Biology | - |
| dc.relation.journalResearchArea | Research & Experimental Medicine | - |
| dc.relation.journalWebOfScienceCategory | Cell Biology | - |
| dc.relation.journalWebOfScienceCategory | Medicine, Research & Experimental | - |
| dc.subject.keywordPlus | REAL-TIME | - |
| dc.subject.keywordPlus | SENSOR | - |
| dc.subject.keywordPlus | ELECTRONICS | - |
| dc.subject.keywordPlus | LACTATE | - |
| dc.subject.keywordPlus | BIOSENSORS | - |
| dc.subject.keywordPlus | SECRETION | - |
| dc.subject.keywordPlus | PRESSURE | - |
| dc.subject.keywordPlus | PLATFORM | - |
| dc.subject.keywordPlus | SYSTEMS | - |
| dc.subject.keywordPlus | DENSITY | - |
| dc.identifier.url | https://www.science.org/doi/epdf/10.1126/scitranslmed.aaf2593 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
