Cited 0 time in
A dual-function chromium-trapping current collector enabling poisoning-free and durable high-temperature fuel cells
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Park, Sun-Young | - |
| dc.contributor.author | Jo, Kanghee | - |
| dc.contributor.author | Hwang, Seongyeon | - |
| dc.contributor.author | Kang, HeeChan | - |
| dc.contributor.author | Park, Mi Young | - |
| dc.contributor.author | Kim, Hyo-Jin | - |
| dc.contributor.author | Park, Jinhong | - |
| dc.contributor.author | Lee, Insung | - |
| dc.contributor.author | Ko, Min Jae | - |
| dc.contributor.author | Kim, Jun Hyuk | - |
| dc.contributor.author | Kim, Kyeounghak | - |
| dc.contributor.author | Kim, Jae Jin | - |
| dc.contributor.author | Yoon, Kyung Joong | - |
| dc.date.accessioned | 2026-06-26T02:30:51Z | - |
| dc.date.available | 2026-06-26T02:30:51Z | - |
| dc.date.issued | 2026-10 | - |
| dc.identifier.issn | 0926-3373 | - |
| dc.identifier.issn | 1873-3883 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/217616 | - |
| dc.description.abstract | High-temperature degradation remains a critical barrier to solid oxide fuel cell (SOFC) commercialization, with Cr vapor–induced electrode poisoning representing one of the most persistent challenges. Here, we present a Co–Ni spinel oxide as a dual-function current collector that actively scavenges Cr vapor while maintaining efficient electrical coupling between the cell and interconnects. Upon Cr exposure, the spinel incorporates Cr via preferential substitution at octahedral Co sites, assisted by Ni acting as a redox-flexible mediator, thereby enabling effective Cr interception without compromising electrical conductivity. Foam- and porous-layer-type Cr-trapping current collectors were developed for practical implementation in realistic SOFC systems. Under severe Cr exposure, reference cells exhibited a 17.6% performance loss over 200 h, whereas cells incorporating the Cr-trapping collector showed complete suppression of degradation, demonstrating robust and sustained electrode protection. This strategy provides a simple, scalable, and effective route to enhancing SOFC durability and extending system lifetime. | - |
| dc.format.extent | 11 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Elsevier | - |
| dc.title | A dual-function chromium-trapping current collector enabling poisoning-free and durable high-temperature fuel cells | - |
| dc.type | Article | - |
| dc.publisher.location | 네덜란드 | - |
| dc.identifier.doi | 10.1016/j.apcatb.2026.126906 | - |
| dc.identifier.scopusid | 2-s2.0-105037869667 | - |
| dc.identifier.wosid | 001766496800001 | - |
| dc.identifier.bibliographicCitation | Applied Catalysis B: Environmental, v.395, pp 1 - 11 | - |
| dc.citation.title | Applied Catalysis B: Environmental | - |
| dc.citation.volume | 395 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 11 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Chemistry | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalWebOfScienceCategory | Chemistry, Physical | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Environmental | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Chemical | - |
| dc.subject.keywordPlus | METALLIC INTERCONNECTS | - |
| dc.subject.keywordPlus | CATHODES | - |
| dc.subject.keywordPlus | DEGRADATION | - |
| dc.subject.keywordPlus | DEPOSITION | - |
| dc.subject.keywordPlus | CO3O4 | - |
| dc.subject.keywordAuthor | Cathode | - |
| dc.subject.keywordAuthor | Chromium | - |
| dc.subject.keywordAuthor | Degradation | - |
| dc.subject.keywordAuthor | Poisoning | - |
| dc.subject.keywordAuthor | Solid oxide fuel cell | - |
| dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S0926337326005266?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.