Cited 0 time in
Membrane-based quasi-isothermal humidifier: Performance characteristics and energy–exergy analysis for HVAC applications
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Cheon, Seong-Yong | - |
| dc.contributor.author | Cho, Hye-Jin | - |
| dc.contributor.author | Jeong, Jae-Weon | - |
| dc.date.accessioned | 2026-06-29T05:00:44Z | - |
| dc.date.available | 2026-06-29T05:00:44Z | - |
| dc.date.issued | 2026-05 | - |
| dc.identifier.issn | 2352-7102 | - |
| dc.identifier.issn | 2352-7102 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/217705 | - |
| dc.description.abstract | Maintaining appropriate indoor humidity during winter is critical for occupant health and comfort. However, conventional heating, ventilation, and air-conditioning (HVAC) humidifiers, such as steam injection, ultrasonic atomization, and direct evaporative systems, often involve either high-grade heat consumption, aerosol carryover concerns, or additional reheating requirements. In this study, a membrane-based quasi-isothermal humidifier (QIMH) was investigated as an alternative humidification approach for HVAC applications. A two-dimensional steady-state heat- and mass-transfer model for a cross-flow hollow-fiber membrane module was developed and validated against laboratory-scale experimental data. Parametric simulations were then conducted by varying inlet water temperature and the air and water flow rates to identify the operating region satisfying the study-defined quasi-isothermal criterion of |ΔTa| ≤ 0.5 °C. The results showed that quasi-isothermal operation is achieved when the inlet water temperature is maintained close to the inlet air temperature and the water flow rate is sufficiently high to supply latent heat without causing appreciable sensible heating or cooling of the air. Under these conditions, the membrane humidifier delivered humidification with near-theoretical thermal efficiency while avoiding the downstream reheating penalty associated with evaporative humidification. An HVAC-oriented exergy comparison under identical outlet-air conditions further showed that the membrane humidifier achieved the highest average exergy efficiency (10.2%), followed by evaporative humidification with reheat (8.9%) and steam injection (5.4%). These results demonstrate the thermodynamic potential of membrane-based quasi-isothermal humidification using low-grade heat in winter HVAC applications. | - |
| dc.format.extent | 14 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Elsevier Ltd | - |
| dc.title | Membrane-based quasi-isothermal humidifier: Performance characteristics and energy–exergy analysis for HVAC applications | - |
| dc.title.alternative | Membrane-based quasi-isothermal humidifier: Performance characteristics and energy-exergy analysis for HVAC applications | - |
| dc.type | Article | - |
| dc.publisher.location | 네덜란드 | - |
| dc.identifier.doi | 10.1016/j.jobe.2026.116139 | - |
| dc.identifier.scopusid | 2-s2.0-105036529932 | - |
| dc.identifier.wosid | 001757642000001 | - |
| dc.identifier.bibliographicCitation | Journal of Building Engineering, v.125, pp 1 - 14 | - |
| dc.citation.title | Journal of Building Engineering | - |
| dc.citation.volume | 125 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 14 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Construction & Building Technology | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalWebOfScienceCategory | Construction & Building Technology | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Civil | - |
| dc.subject.keywordPlus | Evaporation | - |
| dc.subject.keywordPlus | Evaporative cooling systems | - |
| dc.subject.keywordPlus | Exergy | - |
| dc.subject.keywordPlus | Flow of water | - |
| dc.subject.keywordPlus | High temperature operations | - |
| dc.subject.keywordPlus | HVAC | - |
| dc.subject.keywordPlus | Industrial heating | - |
| dc.subject.keywordPlus | Isotherms | - |
| dc.subject.keywordPlus | Mass transfer | - |
| dc.subject.keywordPlus | Membranes | - |
| dc.subject.keywordPlus | Oil well flooding | - |
| dc.subject.keywordPlus | Temperature | - |
| dc.subject.keywordAuthor | Energy | - |
| dc.subject.keywordAuthor | Exergy analysis | - |
| dc.subject.keywordAuthor | Membrane humidifier | - |
| dc.subject.keywordAuthor | Quasi-isothermal humidifier | - |
| dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S2352710226009605?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.