Detailed Information

Cited 0 time in webofscience Cited 1 time in scopus
Metadata Downloads

A three-phase copper MOF-graphene-polyaniline composite for effective sensing of ammonia (vol 1040, pg 89, 2018)

Full metadata record
DC Field Value Language
dc.contributor.authorBhardwaj, Sanjeev K.-
dc.contributor.authorMohanta, Girish C.-
dc.contributor.authorSharma, Amit L.-
dc.contributor.authorKim, Ki-Hyun-
dc.contributor.authorDeep, Akash-
dc.date.accessioned2021-07-30T04:55:15Z-
dc.date.available2021-07-30T04:55:15Z-
dc.date.created2021-05-11-
dc.date.issued2019-07-
dc.identifier.issn0003-2670-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/2182-
dc.description.abstractIn the original article published in last year's December issue, Volume 1043, the Graphical Abstract (GA) was accidentally replaced by one other figure from manuscipt. Further, in the final revison, it was not properly replaced accidentally. Readers may refer to the fact that the wrong old GA (shown below as Fig. 1) should be replaced with the proper GA (shown below as Fig. 2). [Figure presented] In addition, there are a few other corrections that need the attention. [1] Page 91, Line 3 (Right Column), “Sensitivity” should be replaced by “Response”. [2] Page 91, Equation 2: ΔR = Ri. Here, i should be subscrpited, if possible, as ΔR = R i . [3] Page 93, Equation 3: SiO2CuOF - graphene -Pani + + NH 3 → The earlier part of equation should be subscrpited as SiO 2 CuOF - graphene -Pani + + NH 3 . [4] Page 94, information regarding Fig. 8 is not correct. The legend for Fig. 8 on y-axis should be “Response” instead of sensitivity. The replacement (corrected) of Fig 8 for the original article is also provided below as Fig. 4. [Figure presented] All authors apologize these mistakes. These errors are nonetheless not important enough to change the scientific conclusions of the article in any way. It is requested to ammend the suggested changes in the article.-
dc.language영어-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE BV-
dc.titleA three-phase copper MOF-graphene-polyaniline composite for effective sensing of ammonia (vol 1040, pg 89, 2018)-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Ki-Hyun-
dc.identifier.doi10.1016/j.aca.2019.03.010-
dc.identifier.scopusid2-s2.0-85063014053-
dc.identifier.wosid000462290800017-
dc.identifier.bibliographicCitationANALYTICA CHIMICA ACTA, v.1061, pp.169 - 170-
dc.relation.isPartOfANALYTICA CHIMICA ACTA-
dc.citation.titleANALYTICA CHIMICA ACTA-
dc.citation.volume1061-
dc.citation.startPage169-
dc.citation.endPage170-
dc.type.rimsART-
dc.type.docTypeCorrection-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S0003267019302831?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 건설환경공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ki Hyun photo

Kim, Ki Hyun
COLLEGE OF ENGINEERING (DEPARTMENT OF CIVIL AND ENVIRONMENTAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE