Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Topological Prior Vector for quantifying PPG waveform morphology: Metrological characteristics and a hemodynamic state monitoring demonstration

Full metadata record
DC Field Value Language
dc.contributor.authorYi, Myung-Kyu-
dc.contributor.authorLee, Jongshill-
dc.contributor.authorLee, Jeyeon-
dc.contributor.authorKim, In Young-
dc.date.accessioned2026-07-08T11:00:41Z-
dc.date.available2026-07-08T11:00:41Z-
dc.date.issued2026-09-
dc.identifier.issn0263-2241-
dc.identifier.issn1873-412X-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/218433-
dc.description.abstractPhotoplethysmography (PPG) waveform analysis for wearable monitoring remains challenging because waveform quantification is easily affected by noise, sampling variability, fiducial-point uncertainty, and strong inter-subject differences. To address this problem, we propose the Topological Prior Vector (TPV), a deterministic 33-dimensional descriptor that transforms persistent-homology-derived topology into an explicitly defined and reproducible statistical representation of global PPG morphology. Unlike rhythm-oriented variability metrics or fiducial-dependent waveform indices, TPV summarizes the structural organization of delay-embedded pulse trajectories through fixed statistical summaries of birth, death, lifetime, dispersion, complexity, and entropy. We evaluate TPV from a measurement-oriented perspective by examining repeatability, perturbation robustness, and statistical sensitivity to waveform variation on two public datasets. The results show that TPV preserves stable within-subject morphology profiles and remains consistent under controlled signal degradation. In addition, TPV exhibits state-dependent statistical associations across blood-pressure-defined groups, with clearer monotonic tendencies in normotensive conditions and attenuated relationships in hypertensive conditions, suggesting that waveform-topology coupling is regime-dependent rather than uniformly linear. As an initial downstream validation for normotensive versus hypertensive state discrimination, TPV was further evaluated using conventional tree-based classifiers. In intra-subject and inter-subject settings, Random Forest achieved AUCs of 0.83 and 0.75, respectively, while LightGBM yielded AUCs of 0.80 and 0.779, supporting the representational utility of TPV across different classifier choices. These findings suggest that TPV is best understood not as a direct physiological surrogate, but as a compact, reproducible, and measurement-oriented statistical descriptor for profiling global waveform structure under wearable sensing uncertainty.-
dc.format.extent16-
dc.language영어-
dc.language.isoENG-
dc.publisherElsevier B.V.-
dc.titleTopological Prior Vector for quantifying PPG waveform morphology: Metrological characteristics and a hemodynamic state monitoring demonstration-
dc.typeArticle-
dc.publisher.location영국-
dc.identifier.doi10.1016/j.measurement.2026.122168-
dc.identifier.scopusid2-s2.0-105042640791-
dc.identifier.wosid001808025300001-
dc.identifier.bibliographicCitationMeasurement: Journal of the International Measurement Confederation, v.285, pp 1 - 16-
dc.citation.titleMeasurement: Journal of the International Measurement Confederation-
dc.citation.volume285-
dc.citation.startPage1-
dc.citation.endPage16-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryEngineering, Multidisciplinary-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.subject.keywordPlusClassification (of information)-
dc.subject.keywordPlusDecision trees-
dc.subject.keywordPlusDemonstrations-
dc.subject.keywordPlusHemodynamics-
dc.subject.keywordPlusMorphology-
dc.subject.keywordPlusRandom forests-
dc.subject.keywordPlusStatistics-
dc.subject.keywordPlusUncertainty analysis-
dc.subject.keywordPlusVector quantization-
dc.subject.keywordPlusWaveform analysis-
dc.subject.keywordPlusWearable sensors-
dc.subject.keywordAuthorMeasurement repeatability-
dc.subject.keywordAuthorPersistent homology-
dc.subject.keywordAuthorPhotoplethysmography-
dc.subject.keywordAuthorTopological prior vector-
dc.subject.keywordAuthorWaveform morphology quantification-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S0263224126018774?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 의공학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Jeyeon photo

Lee, Jeyeon
서울 의과대학 (DEPARTMENT OF BIOMEDICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE