Detailed Information

Cited 6 time in webofscience Cited 3 time in scopus
Metadata Downloads

Tensile actuators of carbon nanotube coiled yarn based on polydiacetylene-pluronic copolymers as temperature indicators

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Hee Uk-
dc.contributor.authorKim, Hyunsoo-
dc.contributor.authorChun, Kyoung-Yong-
dc.contributor.authorKwon, Cheong Hoon-
dc.contributor.authorLima, Marcio D.-
dc.contributor.authorBaughman, Ray H.-
dc.contributor.authorKIM, SEON JEONG-
dc.date.accessioned2021-08-02T16:30:03Z-
dc.date.available2021-08-02T16:30:03Z-
dc.date.issued2016-07-
dc.identifier.issn0964-1726-
dc.identifier.issn1361-665X-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/22332-
dc.description.abstractMost polydiacetylenes (PDAs) have been studied as chromatic sensors or temperature indicators because of their phase transition that is accompanied by a color change from blue to red. Here, we focus on the structural change based on the polydiacetylene phase transition for a temperature-responsive tensile actuator at low temperature using a copolymer composed of PDA and pluronic in a multi-walled carbon nanotube (MWCNT) coiled yarn. In this paper, we do not focus on the general color change phenomenon of PDA. We demonstrate that the volume change of PDA in the MWCNT coiled yarn provides similar to 180% tensile strain at low temperature (similar to 53 degrees C). Insertion of the pluronic copolymer into the coiled yarn composed of PDA and MWCNT caused the tensile actuation temperature to decrease by similar to 6 degrees C (with tensile actuation of similar to 230%) compared to an actuator without pluronic copolymer. Furthermore, we could verify that the large tensile actuation was also predominantly affected by the melting of the nonpolymerized diacetylene (DA) monomer and the pluronic copolymer. MWCNT coiled yarn actuators with PDA-pluronic copolymer can be easily prepared, have a large tensile actuation, and are actuated at low temperature. It could be used as temperature indicators in the food, drugs, and medical fields.-
dc.format.extent7-
dc.language영어-
dc.language.isoENG-
dc.publisherInstitute of Physics Publishing-
dc.titleTensile actuators of carbon nanotube coiled yarn based on polydiacetylene-pluronic copolymers as temperature indicators-
dc.typeArticle-
dc.publisher.location영국-
dc.identifier.doi10.1088/0964-1726/25/7/075021-
dc.identifier.scopusid2-s2.0-84975284988-
dc.identifier.wosid000381517900024-
dc.identifier.bibliographicCitationSmart Materials and Structures, v.25, no.7, pp 1 - 7-
dc.citation.titleSmart Materials and Structures-
dc.citation.volume25-
dc.citation.number7-
dc.citation.startPage1-
dc.citation.endPage7-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalResearchAreaMaterials Science-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryMaterials Science, Multidisciplinary-
dc.subject.keywordPlusPROTEIN ADSORPTION-
dc.subject.keywordPlusPHASE-TRANSITION-
dc.subject.keywordPlusPOLYMERIZATION-
dc.subject.keywordPlusCRYSTALS-
dc.subject.keywordPlusGRAPHENE-
dc.subject.keywordPlusFILMS-
dc.subject.keywordAuthorpolydiacetylene-
dc.subject.keywordAuthorpluronic copolymer-
dc.subject.keywordAuthortensile actuation-
dc.subject.keywordAuthortemperature indicator-
dc.subject.keywordAuthorMWCNT-
dc.identifier.urlhttps://iopscience.iop.org/article/10.1088/0964-1726/25/7/075021-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Seon Jeong photo

Kim, Seon Jeong
COLLEGE OF ENGINEERING (서울 바이오메디컬공학전공)
Read more

Altmetrics

Total Views & Downloads

BROWSE