Cited 0 time in
축류 팬 허브의 홀 형상 최적화를 통한 모터 열 해석 및 유동특성에 대한 수치해석적 연구
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 강우제 | - |
| dc.contributor.author | 이현규 | - |
| dc.contributor.author | 이정수 | - |
| dc.contributor.author | 조진수 | - |
| dc.date.accessioned | 2021-07-30T04:56:15Z | - |
| dc.date.available | 2021-07-30T04:56:15Z | - |
| dc.date.issued | 2019-02 | - |
| dc.identifier.issn | 2287-9706 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/2254 | - |
| dc.description.abstract | The motor used to drive an axial flow fan generates heat due to internal resistance, which negatively affects performance and shortens the fan’s life span. In this study, cooling of the fan motor using the passive flow control (PFC) method was employed via the hole shape optimization of the axial fan hub. Four design parameters were selected and design points were created using an optimal space-filling design method. The Kriging model was used to construct the response surface. The optimization process using the multi-objective genetic algorithm (MOGA) was performed until the error between the candidate value and the CFD value was less than 0.1%. By comparing the candidate with the initial shape, the optimized shape generated air flow from the back to the front of the axial fan hub. The maximum temperature of the motor was reduced by 17.47 K under the same rotational speed. Conversely, the temperature was further reduced by 6.21 K when compared with the initial shape and operated at the same total pressure. | - |
| dc.format.extent | 8 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국유체기계학회 | - |
| dc.title | 축류 팬 허브의 홀 형상 최적화를 통한 모터 열 해석 및 유동특성에 대한 수치해석적 연구 | - |
| dc.title.alternative | Numerical Study on Thermal Analysis of Motor and Flow Characteristics by Optimizing Hole Shape of Axial Fan Hub | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.5293/kfma.2019.22.1.019 | - |
| dc.identifier.bibliographicCitation | 한국유체기계학회 논문집, v.22, no.1, pp 19 - 26 | - |
| dc.citation.title | 한국유체기계학회 논문집 | - |
| dc.citation.volume | 22 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 19 | - |
| dc.citation.endPage | 26 | - |
| dc.identifier.kciid | ART002436398 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Air-cooling(공냉) | - |
| dc.subject.keywordAuthor | Axial fan(축류 팬) | - |
| dc.subject.keywordAuthor | Computational fluid dynamics(전산유체해석) | - |
| dc.subject.keywordAuthor | Design optimization(최적화 설계) | - |
| dc.subject.keywordAuthor | Passive flow control(피동유동제어) | - |
| dc.subject.keywordAuthor | Thermal analysis(열 해석) | - |
| dc.identifier.url | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE07612263&language=ko_KR&hasTopBanner=true# | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
