Detailed Information

Cited 0 time in webofscience Cited 1 time in scopus
Metadata Downloads

Gamma electron vertex imaging for in-vivo beam-range measurement in proton therapy: Experimental results

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Chan Hyeong-
dc.contributor.authorLee, Han Rim-
dc.contributor.authorKim, Sung Hun-
dc.contributor.authorPark, Jong Hoon-
dc.contributor.authorCho, Sungkoo-
dc.contributor.authorJung, Won Gyun-
dc.date.accessioned2021-07-30T04:56:27Z-
dc.date.available2021-07-30T04:56:27Z-
dc.date.issued2018-09-
dc.identifier.issn0003-6951-
dc.identifier.issn1077-3118-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/2310-
dc.description.abstractProton therapy, thanks to the dose characteristics of the Bragg peak, according to which most of the radiation energy is delivered at the end of the beam with a very high dose gradient at the distal edge, can deliver a highly conformal radiation dose to the treatment volume. Currently, however, the benefit of this high dose gradient is not fully utilized in clinical practice due mainly to the dose-distribution uncertainty in the beam direction (i.e., the uncertainty of the beam range in the patient). In this paper, we present an imaging system based on gamma electron vertex imaging (GEVI), which is suitable for high-energy (1-30 MeV) gammas, and test its performance for therapeutic proton beams. GEVI images prompt gamma vertices, which are closely correlated with the dose distribution at the distal edge, by converting prompt gammas to electrons via Compton scattering and then tracking the recoiled electrons. Our experimental results show that the GEVI system can image the 2D vertices of the prompt gammas and, thus, can be utilized for the measurement of proton-beam ranges in patients. We believe, indeed, that GEVI makes possible real-time monitoring of in-vivo proton-beam ranges, whose utility significantly improves treatment effectiveness and enhances patient safety. We also expect that the GEVI system will find applications in other fields (e.g., gamma-ray astronomy, nuclear engineering, and high-energy physics) requiring high-energy-gamma (1-30 MeV) imaging.-
dc.format.extent6-
dc.language영어-
dc.language.isoENG-
dc.publisherAmerican Institute of Physics-
dc.titleGamma electron vertex imaging for in-vivo beam-range measurement in proton therapy: Experimental results-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1063/1.5039448-
dc.identifier.scopusid2-s2.0-85053210423-
dc.identifier.wosid000444756300041-
dc.identifier.bibliographicCitationApplied Physics Letters, v.113, no.11, pp 1 - 6-
dc.citation.titleApplied Physics Letters-
dc.citation.volume113-
dc.citation.number11-
dc.citation.startPage1-
dc.citation.endPage6-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryPhysics, Applied-
dc.subject.keywordPlusCOMPTON CAMERA-
dc.subject.keywordPlusVERIFICATION-
dc.subject.keywordPlusSYSTEM-
dc.subject.keywordPlusRAYS-
dc.identifier.urlhttps://aip.scitation.org/doi/10.1063/1.5039448-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE