Detailed Information

Cited 6 time in webofscience Cited 5 time in scopus
Metadata Downloads

Position-sensitive NaI(TL) detector module for large-area Compton camera

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Young su-
dc.contributor.authorKim, Jae Hyeon-
dc.contributor.authorLee, Hyun Su-
dc.contributor.authorKim, Chan Hyeong-
dc.date.accessioned2021-07-30T04:58:26Z-
dc.date.available2021-07-30T04:58:26Z-
dc.date.created2021-05-12-
dc.date.issued2018-01-
dc.identifier.issn0374-4884-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/2442-
dc.description.abstractIn the present study, we developed a position-sensitive NaI(Tl) scintillation detector module for use in the development of a large-area Compton camera. The developed detector module employs a large (i.e., 27 x 27 x 2 cm(3)) monolithic NaI(Tl) scintillator coupled with a closely packed array of 6 x 6 square PMTs. A multiplexer-based signal processing circuit and a data acquisition system were developed to estimate the interaction position in the scintillator from the signals of the PMTs by using the maximum likelihood position estimation algorithm (MLPE). The performance of the developed detector was evaluated experimentally, showing that the energy and the time resolution of the detector are 7.88% (for 662-keV gamma ray) and 9.6 ns FWHM, respectively, which are comparable to those of a commercial three-inch cylindrical NaI(Tl) scintillation detector. In addition, the spatial resolutions were about 3-to-6-mm FWHM for a wide energy range (59.5 - 1173 keV) and various interaction positions on the detector (from center to edge), which are satisfactory results considering that a 3-mm-diameter collimated gamma-ray beam was used in the experiments.-
dc.language영어-
dc.language.isoen-
dc.publisherKOREAN PHYSICAL SOC-
dc.titlePosition-sensitive NaI(TL) detector module for large-area Compton camera-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Chan Hyeong-
dc.identifier.doi10.3938/jkps.72.26-
dc.identifier.scopusid2-s2.0-85040058531-
dc.identifier.wosid000419615800005-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.72, no.1, pp.26 - 32-
dc.relation.isPartOfJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.titleJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.volume72-
dc.citation.number1-
dc.citation.startPage26-
dc.citation.endPage32-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART002307845-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryPhysics, Multidisciplinary-
dc.subject.keywordPlusPERFORMANCE-
dc.subject.keywordPlusSIMULATION-
dc.subject.keywordPlusIMAGER-
dc.subject.keywordAuthorLarge monolithic scintillation detector-
dc.subject.keywordAuthorMLPE-
dc.subject.keywordAuthorPosition-sensitive detector-
dc.subject.keywordAuthorMultiplexer-
dc.subject.keywordAuthorCompton camera-
dc.identifier.urlhttps://link.springer.com/article/10.3938/jkps.72.26-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE