Cited 2 time in
A robotic orthosis with a cable-differential mechanism
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Park, Jaehwan | - |
| dc.contributor.author | Park, Seunghan | - |
| dc.contributor.author | Park, Chan Ho | - |
| dc.contributor.author | Jung, Seungmin | - |
| dc.contributor.author | Kim, Chankyu | - |
| dc.contributor.author | Park, Jong Hyeon | - |
| dc.contributor.author | Choi, Junho | - |
| dc.date.accessioned | 2021-07-30T04:58:33Z | - |
| dc.date.available | 2021-07-30T04:58:33Z | - |
| dc.date.issued | 2017-07 | - |
| dc.identifier.issn | 1050-4729 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/2467 | - |
| dc.description.abstract | Robotic orthoses have potential to assist people having difficulty in walking due to their neurological disorders. However, it is important to design lighter orthoses since additional weight and inertia from the device cause discomfort to the wearer and even instability during walking in some extreme cases. To address this problem, a robotic orthosis with a cable differential mechanism is proposed in this paper. It is designed to assist stroke patients with hemiplegia. It has 2 active degrees of freedom at the hip and knee joints and one passive degree of freedom at the ankle. A cable differential mechanism is used to transmit the torques generated by the actuators, which are located near the pelvis of the wearer to reduce the inertial effect. The cable differential mechanism allows for the actuators to share the load with each other, which results in decrease of the maximum required torques by the actuators. Therefore, smaller actuators are possible to be used for further reduction of the weight. The proposed robotic orthosis with a cable differential mechanism, which is called 'COWALK-Mobile 2,' is implemented and evaluated. | - |
| dc.format.extent | 5 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | IEEE | - |
| dc.title | A robotic orthosis with a cable-differential mechanism | - |
| dc.type | Article | - |
| dc.identifier.doi | 10.1109/ICRA.2017.7989065 | - |
| dc.identifier.scopusid | 2-s2.0-85027997126 | - |
| dc.identifier.bibliographicCitation | Proceedings - IEEE International Conference on Robotics and Automation, pp 517 - 521 | - |
| dc.citation.title | Proceedings - IEEE International Conference on Robotics and Automation | - |
| dc.citation.startPage | 517 | - |
| dc.citation.endPage | 521 | - |
| dc.type.docType | Conference Paper | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.subject.keywordPlus | Actuators | - |
| dc.subject.keywordPlus | Cables | - |
| dc.subject.keywordPlus | Degrees of freedom (mechanics) | - |
| dc.subject.keywordPlus | Joints (anatomy) | - |
| dc.subject.keywordPlus | Orthotics | - |
| dc.subject.keywordPlus | Walking aids | - |
| dc.subject.keywordPlus | Degree of freedom | - |
| dc.subject.keywordPlus | Hip and knees | - |
| dc.subject.keywordPlus | Inertial effect | - |
| dc.subject.keywordPlus | Neurological disorders | - |
| dc.subject.keywordPlus | Orthoses | - |
| dc.subject.keywordPlus | Robotic orthose | - |
| dc.subject.keywordPlus | Robotic orthosis | - |
| dc.subject.keywordPlus | Stroke patients | - |
| dc.subject.keywordPlus | Robotics | - |
| dc.identifier.url | https://ieeexplore.ieee.org/document/7989065/ | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
