Detailed Information

Cited 11 time in webofscience Cited 11 time in scopus
Metadata Downloads

Test on the Reliability of Gastight Syringes as Transfer/Storage Media for Gaseous VOC Analysis: The Extent of VOC Sorption between the Inner Needle and a Glass Wall Surface

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Yong-Hyun-
dc.contributor.authorKim, Ki-Hyun-
dc.date.accessioned2021-08-02T18:26:36Z-
dc.date.available2021-08-02T18:26:36Z-
dc.date.created2021-05-12-
dc.date.issued2015-03-
dc.identifier.issn0003-2700-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/25634-
dc.description.abstractA gastight syringe (GTS) is commonly used as a medium for transfer or storage of gaseous standards (or samples) in the analysis of volatile organic compounds (VOCs). In this study, the sorptive loss patterns of 21 VOCs were examined, using GTS as the transfer medium. The results of the test were evaluated with respect to a number of key variables including concentration, sampling volume, and physicochemical properties (molecular weight and boiling point). The VOCs with relatively high volatility (Group 1: aldehyde, ketone, ester, alcohol, and aromatic hydrocarbons (n = 12)) showed low sorptive losses with a mean (± SD) of 2.56 ± 2.87%, regardless of differences in the aforementioned key variables (p-value by t-test before and after using GTS = mean 0.15 ± 0.13). Conversely, the sorptive losses of seven semi-VOCs (Group 2: carboxyl and cresol (n = 9)) were significantly high, ranging from 18.0 ± 4.10% (propionic acid) to 65.4 ± 10.9% (n-heptanonic acid). In addition, we also measured the sorptive losses on the syringe needle (mean sorptive loss of Group 2 = 5.94 ± 5.63%). A linear regression analysis showed that the sorptive losses for Group 2 increased as molecular weight (or boiling point) increased, exhibiting a highly significant correlation (R-2 value (0.804 ± 0.084) and mean p-value (0.002 ± 0.003).-
dc.language영어-
dc.language.isoen-
dc.publisherAMER CHEMICAL SOC-
dc.titleTest on the Reliability of Gastight Syringes as Transfer/Storage Media for Gaseous VOC Analysis: The Extent of VOC Sorption between the Inner Needle and a Glass Wall Surface-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Ki-Hyun-
dc.identifier.doi10.1021/ac504713y-
dc.identifier.scopusid2-s2.0-84924085963-
dc.identifier.wosid000350611700076-
dc.identifier.bibliographicCitationANALYTICAL CHEMISTRY, v.87, no.5, pp.3056 - 3063-
dc.relation.isPartOfANALYTICAL CHEMISTRY-
dc.citation.titleANALYTICAL CHEMISTRY-
dc.citation.volume87-
dc.citation.number5-
dc.citation.startPage3056-
dc.citation.endPage3063-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.subject.keywordPlusVOLATILE ORGANIC-COMPOUNDS-
Files in This Item
There are no files associated with this item.
Appears in
Collections
서울 공과대학 > 서울 건설환경공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ki Hyun photo

Kim, Ki Hyun
COLLEGE OF ENGINEERING (DEPARTMENT OF CIVIL AND ENVIRONMENTAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE