Cited 3 time in
Performance test of a sorbent tube sampler with respect to analyte loss in collecting biogenic volatile organic compounds
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Ullah, Md Ahsan | - |
| dc.contributor.author | Kim, Ki-Hyun | - |
| dc.date.accessioned | 2021-08-02T18:27:21Z | - |
| dc.date.available | 2021-08-02T18:27:21Z | - |
| dc.date.issued | 2015-01 | - |
| dc.identifier.issn | 1618-2642 | - |
| dc.identifier.issn | 1618-2650 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/25668 | - |
| dc.description.abstract | The superiority of thermal desorption-gas chromatography (TD-GC) applications is well known for the analysis of biogenic volatile organic compounds (BVOC). Despite the recognition of potential biases associated with sorptive loss reaction, the interaction of reactive BVOC with a sorbent tube (ST) sampler has not been sufficiently investigated. In this study, the extent of such a loss on a sampling device was studied against the sorbent holder materials by comparing stainless steel (SS; main target) and quartz (QZ; reference). To this end, three bed STs (Tenax TA, Carbopack B, and Carbopack X) were prepared using both holding materials (SS vs. QZ). The extent of BVOC loss was then tested for each material against two different phases (liquid and vapor) of ten monoterpenes. Accordingly, the soptive loss on the SS holder ranged from 10 % (vapor) to 20 % (liquid). If a vapor phase BVOC was forced to pass through an empty SS tube, the extent of their loss increased further in a range of 21.1 % (beta-P) to 43.5 % (alpha-T). Likewise, similar loss rates (about 10 % reductions) were also observed when analyzing some environmental samples (pine needle) from the SS holder relative to QZ. Thus, a QZ tube is recommended over a SS tube to avoid sample loss in the collection of BVOC. | - |
| dc.format.extent | 12 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Springer Verlag | - |
| dc.title | Performance test of a sorbent tube sampler with respect to analyte loss in collecting biogenic volatile organic compounds | - |
| dc.type | Article | - |
| dc.publisher.location | 독일 | - |
| dc.identifier.doi | 10.1007/s00216-014-8258-x | - |
| dc.identifier.scopusid | 2-s2.0-84937866813 | - |
| dc.identifier.wosid | 000348207200006 | - |
| dc.identifier.bibliographicCitation | Analytical and Bioanalytical Chemistry, v.407, no.2, pp 415 - 426 | - |
| dc.citation.title | Analytical and Bioanalytical Chemistry | - |
| dc.citation.volume | 407 | - |
| dc.citation.number | 2 | - |
| dc.citation.startPage | 415 | - |
| dc.citation.endPage | 426 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Biochemistry & Molecular Biology | - |
| dc.relation.journalResearchArea | Chemistry | - |
| dc.relation.journalWebOfScienceCategory | Biochemical Research Methods | - |
| dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
| dc.subject.keywordPlus | REDUCED SULFUR-COMPOUNDS | - |
| dc.subject.keywordPlus | EXPERIMENTAL BIASES | - |
| dc.subject.keywordPlus | GAS-CHROMATOGRAPHY | - |
| dc.subject.keywordPlus | FATTY-ACIDS | - |
| dc.subject.keywordPlus | EMISSIONS | - |
| dc.subject.keywordAuthor | Biogenic volatile organic compound | - |
| dc.subject.keywordAuthor | Stainless steel cartridge | - |
| dc.subject.keywordAuthor | Sorptive loss | - |
| dc.subject.keywordAuthor | Pine needle | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.