Detailed Information

Cited 3 time in webofscience Cited 3 time in scopus
Metadata Downloads

Performance test of a sorbent tube sampler with respect to analyte loss in collecting biogenic volatile organic compounds

Full metadata record
DC Field Value Language
dc.contributor.authorUllah, Md Ahsan-
dc.contributor.authorKim, Ki-Hyun-
dc.date.accessioned2021-08-02T18:27:21Z-
dc.date.available2021-08-02T18:27:21Z-
dc.date.created2021-05-12-
dc.date.issued2015-01-
dc.identifier.issn1618-2642-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/25668-
dc.description.abstractThe superiority of thermal desorption-gas chromatography (TD-GC) applications is well known for the analysis of biogenic volatile organic compounds (BVOC). Despite the recognition of potential biases associated with sorptive loss reaction, the interaction of reactive BVOC with a sorbent tube (ST) sampler has not been sufficiently investigated. In this study, the extent of such a loss on a sampling device was studied against the sorbent holder materials by comparing stainless steel (SS; main target) and quartz (QZ; reference). To this end, three bed STs (Tenax TA, Carbopack B, and Carbopack X) were prepared using both holding materials (SS vs. QZ). The extent of BVOC loss was then tested for each material against two different phases (liquid and vapor) of ten monoterpenes. Accordingly, the soptive loss on the SS holder ranged from 10 % (vapor) to 20 % (liquid). If a vapor phase BVOC was forced to pass through an empty SS tube, the extent of their loss increased further in a range of 21.1 % (beta-P) to 43.5 % (alpha-T). Likewise, similar loss rates (about 10 % reductions) were also observed when analyzing some environmental samples (pine needle) from the SS holder relative to QZ. Thus, a QZ tube is recommended over a SS tube to avoid sample loss in the collection of BVOC.-
dc.language영어-
dc.language.isoen-
dc.publisherSPRINGER HEIDELBERG-
dc.titlePerformance test of a sorbent tube sampler with respect to analyte loss in collecting biogenic volatile organic compounds-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Ki-Hyun-
dc.identifier.doi10.1007/s00216-014-8258-x-
dc.identifier.scopusid2-s2.0-84937866813-
dc.identifier.wosid000348207200006-
dc.identifier.bibliographicCitationANALYTICAL AND BIOANALYTICAL CHEMISTRY, v.407, no.2, pp.415 - 426-
dc.relation.isPartOfANALYTICAL AND BIOANALYTICAL CHEMISTRY-
dc.citation.titleANALYTICAL AND BIOANALYTICAL CHEMISTRY-
dc.citation.volume407-
dc.citation.number2-
dc.citation.startPage415-
dc.citation.endPage426-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaBiochemistry & Molecular Biology-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalWebOfScienceCategoryBiochemical Research Methods-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.subject.keywordPlusREDUCED SULFUR-COMPOUNDS-
dc.subject.keywordPlusEXPERIMENTAL BIASES-
dc.subject.keywordPlusGAS-CHROMATOGRAPHY-
dc.subject.keywordPlusFATTY-ACIDS-
dc.subject.keywordPlusEMISSIONS-
dc.subject.keywordAuthorBiogenic volatile organic compound-
dc.subject.keywordAuthorStainless steel cartridge-
dc.subject.keywordAuthorSorptive loss-
dc.subject.keywordAuthorPine needle-
Files in This Item
There are no files associated with this item.
Appears in
Collections
서울 공과대학 > 서울 건설환경공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ki Hyun photo

Kim, Ki Hyun
COLLEGE OF ENGINEERING (DEPARTMENT OF CIVIL AND ENVIRONMENTAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE