Cited 20 time in
Experimental validation of an effective carbon number-based approach for the gas chromatography-mass spectrometry quantification of 'compounds lacking authentic standards or surrogates'
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Yong-Hyun | - |
| dc.contributor.author | Kim, Ki-Hyun | - |
| dc.contributor.author | Szulejko, Jan E. | - |
| dc.contributor.author | Bae, Min-Suk | - |
| dc.contributor.author | Brown, Richard J. C. | - |
| dc.date.accessioned | 2021-08-02T18:31:04Z | - |
| dc.date.available | 2021-08-02T18:31:04Z | - |
| dc.date.issued | 2014-06 | - |
| dc.identifier.issn | 0003-2670 | - |
| dc.identifier.issn | 1873-4324 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/25874 | - |
| dc.description.abstract | For the quantitative analysis of 'compounds lacking authentic standards or surrogates' (CLASS) in environmental media, we previously introduced an effective carbon number (ECN) approach to develop an empirical equation for the prediction of their response factor (RF). In this research, a series of laboratory experiments were carried out to benchmark the reliability of an ECN approach for sorbent tube/thermal desorption/gas chromatography (GC)/mass spectrometry (MS) applications. First, the ECN values were determined using external calibration data from 25 reference volatile organic compounds (VOCs) using two MS dectectors (quadrupole (Q) and time-of-flight (TOF)). Then, a certified standard mixture of 54 VOCs was analyzed by each system as a simulated unknown sample. The analytical bias, assessed in terms of percentage difference (PD) between the certified and ECN-predicted mass values, averaged 19.2 ± 16.1% (TOF-MS) and 28.2 ± 27.6% (Q-MS). The bias using a more simplified carbon number (CN)-based prediction increased considerably, yielding 53.4 ± 53.3% (TOF-MS) and 61.7 ± 81.3% (Q-MS). However, the bias obtained using the ECN-based prediction decreased significantly to yield average PD values of 9.84 ± 7.28% (TOF-MS) and 16.8 ± 8.35% (Q-MS), if the comparison was limited to 26 (out of 54) VOCs with CN >= 4 (i.e., 25 aromatics and hexachlorobutadiene). (C) 2014 Elsevier B.V. All rights reserved. | - |
| dc.format.extent | 10 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Elsevier BV | - |
| dc.title | Experimental validation of an effective carbon number-based approach for the gas chromatography-mass spectrometry quantification of 'compounds lacking authentic standards or surrogates' | - |
| dc.type | Article | - |
| dc.publisher.location | 네델란드 | - |
| dc.identifier.doi | 10.1016/j.aca.2014.04.052 | - |
| dc.identifier.scopusid | 2-s2.0-84901001411 | - |
| dc.identifier.wosid | 000336390700004 | - |
| dc.identifier.bibliographicCitation | Analytica Chimica Acta, v.830, pp 32 - 41 | - |
| dc.citation.title | Analytica Chimica Acta | - |
| dc.citation.volume | 830 | - |
| dc.citation.startPage | 32 | - |
| dc.citation.endPage | 41 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Chemistry | - |
| dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
| dc.subject.keywordPlus | VOLATILE ORGANIC-COMPOUNDS | - |
| dc.subject.keywordPlus | FLAME IONIZATION DETECTOR | - |
| dc.subject.keywordPlus | RESPONSE FACTORS | - |
| dc.subject.keywordPlus | LIQUID | - |
| dc.subject.keywordPlus | AIR | - |
| dc.subject.keywordPlus | PREDICTION | - |
| dc.subject.keywordPlus | ESTERS | - |
| dc.subject.keywordAuthor | Volatile organic compound | - |
| dc.subject.keywordAuthor | Carbon number | - |
| dc.subject.keywordAuthor | Effective carbon number | - |
| dc.subject.keywordAuthor | Sorbent tube | - |
| dc.subject.keywordAuthor | Thermal desorption | - |
| dc.subject.keywordAuthor | Gas chromatography/mass spectrometry applications | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.