Detailed Information

Cited 7 time in webofscience Cited 7 time in scopus
Metadata Downloads

The application of gas chromatography-time-of-flight mass spectrometry to the analysis of monomethyl mercury at sub-picogram levels

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Yong-Hyun-
dc.contributor.authorKim, Ki Hyun-
dc.contributor.authorYoon, Hye-On-
dc.contributor.authorBrown, Richard J. C.-
dc.date.accessioned2021-08-02T18:54:34Z-
dc.date.available2021-08-02T18:54:34Z-
dc.date.created2021-05-13-
dc.date.issued2013-09-
dc.identifier.issn0026-265X-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/26643-
dc.description.abstractThe analysis of sub-picogram-range methyl mercury generally requires complicated hyphenated instrumentation combining chromatographic systems for the separation and identification of organic Hg components (by GC-MS or LC-MS) and inorganic mass spectrometric techniques for their quantification. To eliminate the complexities and possible biases associated with such complicated hyphenated systems, it is highly desirable to develop a simplified but reliable single-stage instrumental method for the analysis of methyl mercury in environmental samples. To this end, this paper presents an analytical technique based on thermal desorption (TD) - GC - time of flight (TOF) mass spectrometry (MS) for the quantitative analysis of monomethyl mercury (MMHg) prepared in a liquid phase standard. This optimized system was calibrated using standards in the range of 18 pg to 45 ng and yielded a coefficient of correlation of R-2 = 0.9996. This GC-TOF-MS system allowed very low detection limits for MMHg (MDL = 1.86 pg and LOD = 0.031 pg) with good reproducibility (RSE = 1.82%). The potential applicability of the GC-TOF-MS system is highlighted for the trace-level analysis of sub-pg-range of methyl mercury. (C) 2013 Elsevier B.V. All rights reserved.-
dc.language영어-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE BV-
dc.titleThe application of gas chromatography-time-of-flight mass spectrometry to the analysis of monomethyl mercury at sub-picogram levels-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Ki Hyun-
dc.identifier.doi10.1016/j.microc.2013.03.002-
dc.identifier.scopusid2-s2.0-84875773745-
dc.identifier.wosid000326851200016-
dc.identifier.bibliographicCitationMicrochemical Journal, v.110, pp.107 - 112-
dc.relation.isPartOfMicrochemical Journal-
dc.citation.titleMicrochemical Journal-
dc.citation.volume110-
dc.citation.startPage107-
dc.citation.endPage112-
dc.type.rimsART-
dc.type.docType정기학술지(Article(Perspective Article포함))-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.subject.keywordAuthorMonomethyl mercury (MMHg)-
dc.subject.keywordAuthorMethyl mercury chloride (MMC)-
dc.subject.keywordAuthorTime-of-flight mass spectrometry (TOF-MS)-
Files in This Item
There are no files associated with this item.
Appears in
Collections
서울 공과대학 > 서울 건설환경공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ki Hyun photo

Kim, Ki Hyun
COLLEGE OF ENGINEERING (DEPARTMENT OF CIVIL AND ENVIRONMENTAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE