Cited 34 time in
Evaluation of feature extraction methods for EEG-based brain-computer interfaces in terms of robustness to slight changes in electrode locations
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Park, Sun-Ae | - |
| dc.contributor.author | Hwang, Han-Jeong | - |
| dc.contributor.author | Lim, Jeong-Hwan | - |
| dc.contributor.author | Choi, Jong-Ho | - |
| dc.contributor.author | Jung, Hyun-Kyo | - |
| dc.contributor.author | Im, Chang-Hwan | - |
| dc.date.accessioned | 2021-08-02T18:57:00Z | - |
| dc.date.available | 2021-08-02T18:57:00Z | - |
| dc.date.issued | 2013-05 | - |
| dc.identifier.issn | 0140-0118 | - |
| dc.identifier.issn | 1741-0444 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/26735 | - |
| dc.description.abstract | To date, most EEG-based brain-computer interface (BCI) studies have focused only on enhancing BCI performance in such areas as classification accuracy and information transfer rate. In practice, however, test-retest reliability of the developed BCI systems must also be considered for use in long-term, daily life applications. One factor that can affect the reliability of BCI systems is the slight displacement of EEG electrode locations that often occurs due to the removal and reattachment of recording electrodes. The aim of this study was to evaluate and compare various feature extraction methods for motor-imagery-based BCI in terms of robustness to slight changes in electrode locations. To this end, EEG signals were recorded from three reference electrodes (Fz, C3, and C4) and from six additional electrodes located close to the reference electrodes with a 1-cm inter-electrode distance. Eight healthy participants underwent 180 trials of left- and right-hand motor imagery tasks. The performance of four different feature extraction methods [power spectral density (PSD), phase locking value (PLV), a combination of PSD and PLV, and cross-correlation (CC)] were evaluated using five-fold cross-validation and linear discriminant analysis, in terms of robustness to electrode location changes as well as regarding absolute classification accuracy. The quantitative evaluation results demonstrated that the use of either PSD- or CC-based features led to higher classification accuracy than the use of PLV-based features, while PSD-based features showed much higher sensitivity to changes in EEG electrode location than CC- or PLV-based features. Our results suggest that CC can be used as a promising feature extraction method in motor-imagery-based BCI studies, since it provides high classification accuracy along with being little affected by slight changes in the EEG electrode locations. | - |
| dc.format.extent | 9 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Institute of Electrical Engineers | - |
| dc.title | Evaluation of feature extraction methods for EEG-based brain-computer interfaces in terms of robustness to slight changes in electrode locations | - |
| dc.type | Article | - |
| dc.publisher.location | 독일 | - |
| dc.identifier.doi | 10.1007/s11517-012-1026-1 | - |
| dc.identifier.scopusid | 2-s2.0-84885614676 | - |
| dc.identifier.wosid | 000317844500009 | - |
| dc.identifier.bibliographicCitation | Medical & Biological Engineering & Computing, v.51, no.5, pp 571 - 579 | - |
| dc.citation.title | Medical & Biological Engineering & Computing | - |
| dc.citation.volume | 51 | - |
| dc.citation.number | 5 | - |
| dc.citation.startPage | 571 | - |
| dc.citation.endPage | 579 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Computer Science | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalResearchArea | Mathematical & Computational Biology | - |
| dc.relation.journalResearchArea | Medical Informatics | - |
| dc.relation.journalWebOfScienceCategory | Computer Science, Interdisciplinary Applications | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Biomedical | - |
| dc.relation.journalWebOfScienceCategory | Mathematical & Computational Biology | - |
| dc.relation.journalWebOfScienceCategory | Medical Informatics | - |
| dc.subject.keywordPlus | MOTOR IMAGERY | - |
| dc.subject.keywordPlus | PHASE SYNCHRONIZATION | - |
| dc.subject.keywordPlus | CLASSIFICATION | - |
| dc.subject.keywordPlus | TASKS | - |
| dc.subject.keywordAuthor | Brain-computer interface (BCI) | - |
| dc.subject.keywordAuthor | Electroencephalography (EEG) | - |
| dc.subject.keywordAuthor | Electrode-location robustness (ELR) | - |
| dc.subject.keywordAuthor | cross-correlation (CC) | - |
| dc.subject.keywordAuthor | Power spectral density (PSD) | - |
| dc.subject.keywordAuthor | Phase locking value (PLV) | - |
| dc.identifier.url | https://link.springer.com/article/10.1007%2Fs11517-012-1026-1 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
