Calculation of local skin doses with ICRP adult mesh-type reference computational phantoms

Full metadata record
DC Field Value Language
dc.contributor.authorYeom, Yeon Soo-
dc.contributor.authorHan, Haegin-
dc.contributor.authorChoi, Chansoo-
dc.contributor.authorThang Tat Nguyen-
dc.contributor.authorLee, Hanjin-
dc.contributor.authorShin, Bangho-
dc.contributor.authorKim, Chan Hyeong-
dc.contributor.authorHan, Min Cheol-
dc.date.accessioned2021-07-30T05:01:14Z-
dc.date.available2021-07-30T05:01:14Z-
dc.date.created2021-05-12-
dc.date.issued2018-01-
dc.identifier.issn0374-4884-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/2734-
dc.description.abstractRecently, Task Group 103 of the International Commission on Radiological Protection (ICRP) developed new mesh-type reference computational phantoms (MRCPs) for adult males and females in order to address the limitations of the current voxel-type reference phantoms described in ICRP Publication 110 due to their limited voxel resolutions and the nature of the voxel geometry. One of the substantial advantages of the MRCPs over the ICRP-110 reference phantoms is the inclusion of a 50-mu m-thick radiosensitive skin basal-cell layer; however, a methodology for calculating the local skin dose (LSD), i.e., the maximum dose to the basal layer averaged over a 1-cm(2) area, has yet to be developed. In the present study, a dedicated program for the LSD calculation with the MRCPs was developed based on the mean shift algorithm and the Geant4 Monte Carlo code. The developed program was used to calculate local skin dose coefficients (LSDCs) for electrons and alpha particles, which were then compared with the values given in ICRP Publication 116 that were produced with a simple tissue-equivalent cube model. The results of the present study show that the LSDCs of the MRCPs are generally in good agreement with the ICRP-116 values for alpha particles, but for electrons, significant differences are found at energies higher than 0.15 MeV. The LSDCs of the MRCPs are greater than the ICRP-116 values by as much as similar to 2.7 times at 10 MeV, which is due mainly to the different curvature between realistic MRCPs (i.e., curved) and the simple cube model (i.e., flat).-
dc.language영어-
dc.language.isoen-
dc.publisherKOREAN PHYSICAL SOC-
dc.titleCalculation of local skin doses with ICRP adult mesh-type reference computational phantoms-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Chan Hyeong-
dc.identifier.doi10.3938/jkps.72.177-
dc.identifier.scopusid2-s2.0-85040057987-
dc.identifier.wosid000419615800028-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.72, no.1, pp.177 - 182-
dc.relation.isPartOfJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.titleJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.volume72-
dc.citation.number1-
dc.citation.startPage177-
dc.citation.endPage182-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART002307835-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryPhysics, Multidisciplinary-
dc.subject.keywordPlusSIMULATION-
dc.subject.keywordAuthorICRP-
dc.subject.keywordAuthorMesh-type reference phantom-
dc.subject.keywordAuthorLocal skin dose-
dc.subject.keywordAuthorMean shift algorithm-
dc.subject.keywordAuthorGeant4-
dc.identifier.urlhttps://link.springer.com/article/10.3938/jkps.72.177-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE