Cited 5 time in
Development of an effective dose coefficient database using a computational human phantom and Monte Carlo simulations to evaluate exposure dose for the usage of NORM-added consumer products
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Yoo, Do Hyeon | - |
| dc.contributor.author | Shin, Wook-Geun | - |
| dc.contributor.author | Lee, Jaekook | - |
| dc.contributor.author | Yeom, Yeon Soo | - |
| dc.contributor.author | Kim, Chan Hyeong | - |
| dc.contributor.author | Chang, Byung-Uck | - |
| dc.contributor.author | Min, Chul Hee | - |
| dc.date.accessioned | 2021-07-30T05:01:16Z | - |
| dc.date.available | 2021-07-30T05:01:16Z | - |
| dc.date.issued | 2017-11 | - |
| dc.identifier.issn | 0969-8043 | - |
| dc.identifier.issn | 1872-9800 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/2740 | - |
| dc.description.abstract | After the Fukushima accident in Japan, the Korean Government implemented the "Act on Protective Action Guidelines Against Radiation in the Natural Environment" to regulate unnecessary radiation exposure to the public. However, despite the law which came into effect in July 2012, an appropriate method to evaluate the equivalent and effective doses from naturally occurring radioactive material (NORM) in consumer products is not available. The aim of the present study is to develop and validate an effective dose coefficient database enabling the simple and correct evaluation of the effective dose due to the usage of NORM-added consumer products. To construct the database, we used a skin source method with a computational human phantom and Monte Carlo (MC) simulation. For the validation, the effective dose was compared between the database using interpolation method and the original MC method. Our result showed a similar equivalent dose across the 26 organs and a corresponding average dose between the database and the MC calculations of < 5% difference. The differences in the effective doses were even less, and the result generally show that equivalent and effective doses can be quickly calculated with the database with sufficient accuracy. | - |
| dc.format.extent | 7 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Pergamon Press Ltd. | - |
| dc.title | Development of an effective dose coefficient database using a computational human phantom and Monte Carlo simulations to evaluate exposure dose for the usage of NORM-added consumer products | - |
| dc.type | Article | - |
| dc.publisher.location | 영국 | - |
| dc.identifier.doi | 10.1016/j.apradiso.2017.07.064 | - |
| dc.identifier.scopusid | 2-s2.0-85029676479 | - |
| dc.identifier.wosid | 000413058200007 | - |
| dc.identifier.bibliographicCitation | Applied Radiation and Isotopes, v.129, pp 42 - 48 | - |
| dc.citation.title | Applied Radiation and Isotopes | - |
| dc.citation.volume | 129 | - |
| dc.citation.startPage | 42 | - |
| dc.citation.endPage | 48 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Chemistry | - |
| dc.relation.journalResearchArea | Nuclear Science & Technology | - |
| dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.relation.journalWebOfScienceCategory | Chemistry, Inorganic & Nuclear | - |
| dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
| dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.subject.keywordPlus | Consumer products | - |
| dc.subject.keywordPlus | Database systems | - |
| dc.subject.keywordPlus | Intelligent systems | - |
| dc.subject.keywordPlus | Phantoms | - |
| dc.subject.keywordPlus | Radioactive materials | - |
| dc.subject.keywordAuthor | NORM | - |
| dc.subject.keywordAuthor | Consumer products | - |
| dc.subject.keywordAuthor | Equivalent dose | - |
| dc.subject.keywordAuthor | Effective dose | - |
| dc.subject.keywordAuthor | Monte Carlo simulation | - |
| dc.subject.keywordAuthor | Database | - |
| dc.subject.keywordAuthor | Computational human phantom | - |
| dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S0969804317301963?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
