Detailed Information

Cited 4 time in webofscience Cited 3 time in scopus
Metadata Downloads

Effect of emergency core cooling system flow reduction on channel temperature during recirculation phase of large break loss-of-coolant accident at Wolsong unit 1

Full metadata record
DC Field Value Language
dc.contributor.authorYu, Seon Oh-
dc.contributor.authorCho, Yong Jin-
dc.contributor.authorKim, Sung Joong-
dc.date.accessioned2021-07-30T05:01:17Z-
dc.date.available2021-07-30T05:01:17Z-
dc.date.created2021-05-12-
dc.date.issued2017-08-
dc.identifier.issn1738-5733-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/2747-
dc.description.abstractThe feasibility of cooling in a pressurized heavy water reactor after a large break loss-of-coolant accident has been analyzed using Multidimensional Analysis of Reactor Safety-KINS Standard code during the recirculation phase. Through evaluation of sensitivity of the fuel channel temperature to various effective recirculation flow areas, it is determined that proper cooling of the fuel channels in the broken loop is feasible if the effective flow area remains above approximately 70% of the nominal flow area. When the flow area is reduced by more than approximately 25% of the nominal value, however, incipience of boiling is expected, after which the thermal integrity of the fuel channel can be threatened. In addition, if a dramatic reduction of the recirculation flow occurs, excursions and frequent fluctuations of temperature in the fuel channels are likely to be unavoidable, and thus damage to the fuel channels would be anticipated. To resolve this, emergency coolant supply through the newly installed external injection path can be used as one alternative means of cooling, enabling fuel channel integrity to be maintained and permanently preventing severe accident conditions. Thus, the external injection flow required to guarantee fuel channel coolability has been estimated.-
dc.language영어-
dc.language.isoen-
dc.publisherKOREAN NUCLEAR SOC-
dc.titleEffect of emergency core cooling system flow reduction on channel temperature during recirculation phase of large break loss-of-coolant accident at Wolsong unit 1-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Sung Joong-
dc.identifier.doi10.1016/j.net.2017.03.007-
dc.identifier.scopusid2-s2.0-85019904574-
dc.identifier.wosid000410895900010-
dc.identifier.bibliographicCitationNUCLEAR ENGINEERING AND TECHNOLOGY, v.49, no.5, pp.979 - 988-
dc.relation.isPartOfNUCLEAR ENGINEERING AND TECHNOLOGY-
dc.citation.titleNUCLEAR ENGINEERING AND TECHNOLOGY-
dc.citation.volume49-
dc.citation.number5-
dc.citation.startPage979-
dc.citation.endPage988-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART002249739-
dc.description.journalClass1-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.subject.keywordPlusSUMP STRAINER-
dc.subject.keywordPlusHEAD LOSS-
dc.subject.keywordPlusSCREEN-
dc.subject.keywordPlusLOCA-
dc.subject.keywordAuthorExternal Injection Path-
dc.subject.keywordAuthorFuel Channel Cooling-
dc.subject.keywordAuthorLBLOCA-
dc.subject.keywordAuthorLoss of ECCS-
dc.subject.keywordAuthorMARS-KS-
dc.subject.keywordAuthorPHWR-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S1738573317302309?via%3Dihub-
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Sung Joong photo

Kim, Sung Joong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE