Detailed Information

Cited 17 time in webofscience Cited 18 time in scopus
Metadata Downloads

Identification of control parameters for the sulfur gas storability with bag sampling methods

Full metadata record
DC Field Value Language
dc.contributor.authorJo, Sang-Hee-
dc.contributor.authorKim, Ki Hyun-
dc.contributor.authorShon, Zang-Ho-
dc.contributor.authorParker, David-
dc.date.accessioned2021-08-02T19:27:50Z-
dc.date.available2021-08-02T19:27:50Z-
dc.date.created2021-05-13-
dc.date.issued2012-08-
dc.identifier.issn0003-2670-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/27487-
dc.description.abstractAir samples containing sulfur compounds are often collected and stored in sample bags prior to analysis. The storage stability of six gaseous sulfur compounds (H2S, CH3SH, DMS, CS2, DMDS and SO2) was compared between two different bag materials (polyvinyl fluoride (PVF) and polyester aluminum (PEA)) at five initial concentrations (1, 10, 100, 1000, and 10,000 ppb). The response factors (RF) of these samples were determined after storage periods of 0, 1, and 3 days by gas chromatography-pulsed flame photometric detector (GC-PFPD) combined with an air server (AS)/thermal desorber (TD) system. Although concentration reduction occurred more rapidly from samples of the high concentration standards (1000 and 10,000 ppb), such trends were not evident in their low concentration counterparts (1, 10, and 100 ppb). As such, temporal changes in RF values and the associated loss rates of most sulfur gases were greatly affected by their initial concentration levels. Moreover, the storability of oxidized sulfur compound (SO2) was greatly distinguished from that of reduced sulfur compounds (RSCs), as the former almost disappeared in the PVF bag even after one day. The results of our study confirm that storability of gaseous sulfur species is affected interactively by such variables as initial gas concentration level, bag material type, and oxidation status with the associated reactivity. (C) 2012 Elsevier B.V. All rights reserved.-
dc.language영어-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE BV-
dc.titleIdentification of control parameters for the sulfur gas storability with bag sampling methods-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Ki Hyun-
dc.identifier.doi10.1016/j.aca.2012.06.010-
dc.identifier.scopusid2-s2.0-84863853975-
dc.identifier.wosid000306877800007-
dc.identifier.bibliographicCitationANALYTICA CHIMICA ACTA, v.738, pp.51 - 58-
dc.relation.isPartOfANALYTICA CHIMICA ACTA-
dc.citation.titleANALYTICA CHIMICA ACTA-
dc.citation.volume738-
dc.citation.startPage51-
dc.citation.endPage58-
dc.type.rimsART-
dc.type.docType정기학술지(Article(Perspective Article포함))-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.subject.keywordAuthorPolyester aluminum-
dc.subject.keywordAuthorPolyvinyl fluoride-
dc.subject.keywordAuthorReduced sulfur compounds-
dc.subject.keywordAuthorStorage stability-
dc.subject.keywordAuthorTedlar-
Files in This Item
There are no files associated with this item.
Appears in
Collections
서울 공과대학 > 서울 건설환경공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ki Hyun photo

Kim, Ki Hyun
COLLEGE OF ENGINEERING (DEPARTMENT OF CIVIL AND ENVIRONMENTAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE