Detailed Information

Cited 9 time in webofscience Cited 8 time in scopus
Metadata Downloads

Prototype system for proton beam range measurement based on gamma electron vertex imaging

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Han Rim-
dc.contributor.authorKim, Sung Hun-
dc.contributor.authorPark, Jong Hoon-
dc.contributor.authorJung, Won Gyun-
dc.contributor.authorLim, Hansang-
dc.contributor.authorKim, Chan Hyeong-
dc.date.accessioned2021-07-30T05:01:20Z-
dc.date.available2021-07-30T05:01:20Z-
dc.date.issued2017-06-
dc.identifier.issn0168-9002-
dc.identifier.issn1872-9576-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/2756-
dc.description.abstractIn proton therapy, for both therapeutic effectiveness and patient safety, it is very important to accurately measure the proton dose distribution, especially the range of the proton beam. For this purpose, recently we proposed a new imaging method named gamma electron vertex imaging (GEVI), in which the prompt gammas emitting from the nuclear reactions of the proton beam in the patient are converted to electrons, and then the converted electrons are tracked to determine the vertices of the prompt gammas, thereby producing a 2D image of the vertices. In the present study, we developed a prototype GEVI system, including dedicated signal processing and data acquisition systems, which consists of a beryllium plate (= electron converter) to convert the prompt gammas to electrons, two double-sided silicon strip detectors (= hodoscopes) to determine the trajectories of those converted electrons, and a plastic scintillation detector (= calorimeter) to measure their kinetic energies. The system uses triple coincidence logic and multiple energy windows to select only the events from prompt gammas. The detectors of the prototype GEVI system were evaluated for electronic noise level, energy resolution, and time resolution. Finally, the imaging capability of the GEVI system was tested by imaging a Sr-90 beta source, a Co-60 gamma source, and a 45-MeV proton beam in a PMMA phantom. The overall results of the present study generally show that the prototype GEVI system can image the vertices of the prompt gammas produced by the proton nuclear interactions.-
dc.format.extent16-
dc.language영어-
dc.language.isoENG-
dc.publisherElsevier BV-
dc.titlePrototype system for proton beam range measurement based on gamma electron vertex imaging-
dc.typeArticle-
dc.publisher.location네델란드-
dc.identifier.doi10.1016/j.nima.2017.03.022-
dc.identifier.scopusid2-s2.0-85015767142-
dc.identifier.wosid000400716400011-
dc.identifier.bibliographicCitationNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, v.857, pp 82 - 97-
dc.citation.titleNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment-
dc.citation.volume857-
dc.citation.startPage82-
dc.citation.endPage97-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryPhysics, Nuclear-
dc.relation.journalWebOfScienceCategoryPhysics, Particles & Fields-
dc.subject.keywordPlusENERGY CALIBRATION-
dc.subject.keywordPlusCOMPTON CAMERA-
dc.subject.keywordPlusSLIT CAMERA-
dc.subject.keywordPlusVERIFICATION-
dc.subject.keywordAuthorProton therapy-
dc.subject.keywordAuthorProton dose monitoring-
dc.subject.keywordAuthorBeam range measurement-
dc.subject.keywordAuthorPrompt gamma-
dc.subject.keywordAuthorGamma electron vertex imaging-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S0168900217303613?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE