Detailed Information

Cited 11 time in webofscience Cited 11 time in scopus
Metadata Downloads

The use of permeation tube device and the development of empirical formula for accurate permeation rate

Full metadata record
DC Field Value Language
dc.contributor.authorSusaya, Janice-
dc.contributor.authorKim, Ki-Hyun-
dc.contributor.authorCho, Jin Woo-
dc.contributor.authorParker, David-
dc.date.accessioned2021-08-02T19:31:19Z-
dc.date.available2021-08-02T19:31:19Z-
dc.date.created2021-05-13-
dc.date.issued2011-12-
dc.identifier.issn0021-9673-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/27641-
dc.description.abstractA series of laboratory experiments were conducted to assess the accuracy of permeation tube (PT) devices using a calibration gas generator system to measure permeation rate (PR) of volatile organic compounds (VOCs). Calibration gas standards of benzene, toluene, and m-xylene (BTX) were produced from PTs at varying flow rates (FR) of 20-1200 mL min(-1) and constant temperature (30 degrees C). Results indicate that changes in flow rate greatly affected the permeation rate of each VOC at this temperature. This paper presents experimental approaches to accurately measure actual permeation rate (APR) and the derivation of empirical equations for predicted permeation rate (PPR). If the magnitude of bias is defined as the difference between PPR and the manufacturer's permeation rate (MPR), the bias was typically 19-40% for toluene (T) and 31-54% for m-xylene (X). Benzene (B) exhibited the least bias of 1.4-18.8%, nevertheless our PPR values for benzene were more reliable at lower flow rates (0.75-1.20%). This study highlights the importance of flow rate and associated pressure changes as a key to accurate permeation rate estimation from permeation tube devices. (C) 2011 Elsevier B.V. All rights reserved.-
dc.language영어-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE BV-
dc.titleThe use of permeation tube device and the development of empirical formula for accurate permeation rate-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Ki-Hyun-
dc.identifier.doi10.1016/j.chroma.2011.11.007-
dc.identifier.scopusid2-s2.0-82955213007-
dc.identifier.wosid000298530600005-
dc.identifier.bibliographicCitationJOURNAL OF CHROMATOGRAPHY A, v.1218, pp.9328 - 9335-
dc.relation.isPartOfJOURNAL OF CHROMATOGRAPHY A-
dc.citation.titleJOURNAL OF CHROMATOGRAPHY A-
dc.citation.volume1218-
dc.citation.startPage9328-
dc.citation.endPage9335-
dc.type.rimsART-
dc.type.docType정기학술지(Article(Perspective Article포함))-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaBiochemistry & Molecular Biology-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalWebOfScienceCategoryBiochemistry & Molecular Biology-
dc.relation.journalWebOfScienceCategoryChemistry-
dc.subject.keywordAuthorAccuracy-
dc.subject.keywordAuthorBenzene-
dc.subject.keywordAuthorFlow rate-
dc.subject.keywordAuthorPermeation-
dc.subject.keywordAuthorToluene-
dc.subject.keywordAuthorXylene-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S0021967311016736?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 건설환경공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ki Hyun photo

Kim, Ki Hyun
COLLEGE OF ENGINEERING (DEPARTMENT OF CIVIL AND ENVIRONMENTAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE