Detailed Information

Cited 3 time in webofscience Cited 2 time in scopus
Metadata Downloads

Continuously Deforming 4D Voxel Phantom for Realistic Representation of Respiratory Motion in Monte Carlo Dose Calculation

Full metadata record
DC Field Value Language
dc.contributor.authorHan, Min Cheol-
dc.contributor.authorSeo, Jeong Min-
dc.contributor.authorLee, Se Hyung-
dc.contributor.authorKim, Chan Hyeong-
dc.contributor.authorYeom, Yeon Soo-
dc.contributor.authorThang Tat Nguyen-
dc.contributor.authorChoi, Chansoo-
dc.contributor.authorKim, Seonghoon-
dc.contributor.authorJeong, Jong Hwi-
dc.contributor.authorSohn, Jason W.-
dc.date.accessioned2021-07-30T05:04:50Z-
dc.date.available2021-07-30T05:04:50Z-
dc.date.created2021-05-12-
dc.date.issued2016-12-
dc.identifier.issn0018-9499-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/2791-
dc.description.abstractWe propose a new type of computational phantom, the "4D voxel phantom," for realistic modeling of continuous respiratory motion in Monte Carlo dose calculation. In this phantom, continuous respiratory motion is realized by linear interpolation of the deformation vector fields (DVFs) between the neighboring original phases in the 4D CT data of a patient and by subsequent application of the DVFs to the phase images or to the reference image to produce multiple inter-phase images between the neighboring original phase images. A 4D voxel phantom is a combination of high-temporal-resolution voxel phantoms and on-the-fly dose registration to the reference phase image. In the course of particle transport simulation, the dose or deposited energy is directly registered to the reference phase image on-the-fly (i.e., after each event) using a DVF for dose registration. In the present study, we investigated two methods-DRP (DIR [deformable image registration] with respect to Reference Phase image) and DNP (DIR with respect to Neighboring original Phase image) - for production of multiple inter-phase images or high-temporal-resolution voxel phantoms. Utilizing these two methods, two 4D voxel phantoms each with 100 phases were produced from the original 10-phase images of the 4D CT data of a real patient in order to compare the two methods and to test the feasibility of the 4D voxel phantom methodology in general. We found that it is possible to produce a 4D voxel phantom very rapidly (i.e., <40 min on a 4-core personal computer for a 100-phase phantom) in a fully automated process. The dose calculation results showed that the constructed 100-phase 4D voxel phantoms provide cumulative-dose distributions very similar to those of the conventional 10-phase approach for stationary proton-beam irradiation. The passing rates of the dose distributions of the 4D voxel phantoms were higher than 99.9% according to the 3% and 3 mm gamma criteria, which results validate the 4D voxel phantom methodology. The point- and dose-tracking analysis data showed that the DRP method, which uses the minimal number of DIR operations but uses inverse DVFs, provides significantly better results than those of the DNP method, which uses only DIR to generate the DVFs for inter-phase image generation and dose registration. The present study also showed that the computation time does not significantly increase when the number of phases in the 4D voxel phantom is increased for more realistic representation of continuous respiratory motion; the only significant increase is in the memory occupancy, which grows almost linearly with the number of phases.-
dc.language영어-
dc.language.isoen-
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC-
dc.titleContinuously Deforming 4D Voxel Phantom for Realistic Representation of Respiratory Motion in Monte Carlo Dose Calculation-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Chan Hyeong-
dc.identifier.doi10.1109/TNS.2016.2601080-
dc.identifier.scopusid2-s2.0-85012941044-
dc.identifier.wosid000391693100023-
dc.identifier.bibliographicCitationIEEE TRANSACTIONS ON NUCLEAR SCIENCE, v.63, no.6, pp.2918 - 2924-
dc.relation.isPartOfIEEE TRANSACTIONS ON NUCLEAR SCIENCE-
dc.citation.titleIEEE TRANSACTIONS ON NUCLEAR SCIENCE-
dc.citation.volume63-
dc.citation.number6-
dc.citation.startPage2918-
dc.citation.endPage2924-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.subject.keywordPlusLUNG-
dc.subject.keywordPlusTUMOR-
dc.subject.keywordPlusRADIOTHERAPY-
dc.subject.keywordPlusREGISTRATION-
dc.subject.keywordPlusINTERPLAY-
dc.subject.keywordPlusTHERAPY-
dc.subject.keywordPlusSIZE-
dc.subject.keywordAuthor4D dose calculation-
dc.subject.keywordAuthor4D Monte Carlo simulation-
dc.subject.keywordAuthor4D voxel phantom-
dc.identifier.urlhttps://ieeexplore.ieee.org/document/7546842-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE