Detailed Information

Cited 3 time in webofscience Cited 4 time in scopus
Metadata Downloads

Speckle noise reduction for ultrasound images by using speckle reducing anisotropic diffusion and Bayes threshold

Full metadata record
DC Field Value Language
dc.contributor.authorChoi, Hyunho-
dc.contributor.authorJeong, Je chang-
dc.date.accessioned2021-07-30T05:06:01Z-
dc.date.available2021-07-30T05:06:01Z-
dc.date.created2021-05-12-
dc.date.issued2019-
dc.identifier.issn0895-3996-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/2971-
dc.description.abstractUltrasound imaging has been used for diagnosing lesions in the human body. In the process of acquiring ultrasound images, speckle noise may occur, affecting image quality and auto-lesion classification. Despite the efforts to resolve this, conventional algorithms exhibit poor speckle noise removal and edge preservation performance. Accordingly, in this study, a novel algorithm is proposed based on speckle reducing anisotropic diffusion (SRAD) and a Bayes threshold in the wavelet domain. In this algorithm, SRAD is employed as a preprocessing filter, and the Bayes threshold is used to remove the residual noise in the resulting image. Compared to the conventional filtering techniques, experimental results showed that the proposed algorithm exhibited superior performance in terms of peak signal-to-noise ratio (average = 28.61 dB) and structural similarity (average = 0.778).-
dc.language영어-
dc.language.isoen-
dc.publisherIOS PRESS-
dc.titleSpeckle noise reduction for ultrasound images by using speckle reducing anisotropic diffusion and Bayes threshold-
dc.typeArticle-
dc.contributor.affiliatedAuthorJeong, Je chang-
dc.identifier.doi10.3233/XST-190515-
dc.identifier.scopusid2-s2.0-85073740723-
dc.identifier.wosid000492038300007-
dc.identifier.bibliographicCitationJOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, v.27, no.5, pp.885 - 898-
dc.relation.isPartOfJOURNAL OF X-RAY SCIENCE AND TECHNOLOGY-
dc.citation.titleJOURNAL OF X-RAY SCIENCE AND TECHNOLOGY-
dc.citation.volume27-
dc.citation.number5-
dc.citation.startPage885-
dc.citation.endPage898-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalResearchAreaOptics-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryOptics-
dc.relation.journalWebOfScienceCategoryPhysics, Applied-
dc.subject.keywordPlusWAVELET-
dc.subject.keywordPlusENHANCEMENT-
dc.subject.keywordPlusREMOVAL-
dc.subject.keywordPlusFILTER-
dc.subject.keywordAuthorUltrasound imaging-
dc.subject.keywordAuthorspeckle noise-
dc.subject.keywordAuthordiscrete wavelet transform-
dc.subject.keywordAuthorsrad-
dc.subject.keywordAuthorbayes threshold-
Files in This Item
There are no files associated with this item.
Appears in
Collections
서울 공과대학 > 서울 융합전자공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeong, Jechang photo

Jeong, Jechang
COLLEGE OF ENGINEERING (SCHOOL OF ELECTRONIC ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE