Detailed Information

Cited 2 time in webofscience Cited 2 time in scopus
Metadata Downloads

Clinical Utility of Quantitative CT Analysis for Fissure Completeness in Bronchoscopic Lung Volume Reduction: Comparison between CT and Chartis™.

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Sei Won-
dc.contributor.authorShin, So Youn-
dc.contributor.authorPark, Tai Sun-
dc.contributor.authorChoi, Yoon Young-
dc.contributor.authorPark, Jong Chun-
dc.contributor.authorPark, Jina-
dc.contributor.authorOh, Sang Young-
dc.contributor.authorKim, Namkug-
dc.contributor.authorLee, Se Hee-
dc.contributor.authorLee, Jae Seung-
dc.contributor.authorSeo, Joon Beom-
dc.contributor.authorOh, Yeon-Mok-
dc.contributor.authorLee, Sang-Do-
dc.contributor.authorLee, Sang Min-
dc.date.accessioned2021-07-30T05:09:50Z-
dc.date.available2021-07-30T05:09:50Z-
dc.date.created2021-05-14-
dc.date.issued2019-07-
dc.identifier.issn1229-6929-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/3275-
dc.description.abstractObjective: The absence of collateral ventilation (CV) is crucial for effective bronchoscopic lung volume reduction (BLVR) with an endobronchial valve. Here, we assessed whether CT can predict the Chartis™ results. Materials and Methods: This study included 69 patients (mean age: 70.9 ± 6.6 years; 66 [95.7%] males) who had undergone CT to assess BLVR eligibility. The Chartis™ system (Pulmonox Inc.) was used to check CV. Experienced thoracic radiologists independently determined the completeness of fissures on volumetric CT images. Results: The comparison between the visual and quantitative analyses revealed that 5% defect criterion showed good agreement. The Chartis™ assessment was performed for 129 lobes; 11 (19.6%) of 56 lobes with complete fissures on CT showed positive CV, while this rate was significantly higher (40 of 49 lobes, i.e., 81.6%) for lobes with incomplete fissures. The size of the fissure defect did not affect the rate of CV. Of the patients who underwent BLVR, 22 of 24 patients (91.7%) with complete fissures and three of four patients with incomplete fissures (75%) achieved target lobe volume reduction (TLVR). Conclusion: The quantitative analysis of fissure shows that incomplete fissures increased the probability of CV on Chartis™, while the defect size did not affect the overall rates. TLVR could be achieved even in some patients with relatively large fissure defect, if they showed negative CV on Chartis™.-
dc.language영어-
dc.language.isoen-
dc.publisherKOREAN RADIOLOGICAL SOC-
dc.titleClinical Utility of Quantitative CT Analysis for Fissure Completeness in Bronchoscopic Lung Volume Reduction: Comparison between CT and Chartis™.-
dc.typeArticle-
dc.contributor.affiliatedAuthorPark, Tai Sun-
dc.identifier.doi10.3348/kjr.2018.0724-
dc.identifier.scopusid2-s2.0-85069268254-
dc.identifier.wosid000473510900014-
dc.identifier.bibliographicCitationKOREAN JOURNAL OF RADIOLOGY, v.20, no.7, pp.1216 - 1225-
dc.relation.isPartOfKOREAN JOURNAL OF RADIOLOGY-
dc.citation.titleKOREAN JOURNAL OF RADIOLOGY-
dc.citation.volume20-
dc.citation.number7-
dc.citation.startPage1216-
dc.citation.endPage1225-
dc.type.rimsART-
dc.type.docType정기학술지(Article(Perspective Article포함))-
dc.identifier.kciidART002484291-
dc.description.journalClass1-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusCOLLATERAL VENTILATION-
dc.subject.keywordPlusENDOBRONCHIAL VALVES-
dc.subject.keywordPlusEMPHYSEMA-
dc.subject.keywordPlusPREDICTION-
dc.subject.keywordPlusCOLLAPSE-
dc.subject.keywordAuthorChronic obstructive pulmonary disease-
dc.subject.keywordAuthorEmphysema-
dc.subject.keywordAuthorTomography-
dc.subject.keywordAuthorX-ray computed-
dc.identifier.urlhttps://www.kjronline.org/DOIx.php?id=10.3348/kjr.2018.0724-
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 내과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Tai Sun photo

Park, Tai Sun
서울 의과대학 (DEPARTMENT OF INTERNAL MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE