Comparative evaluation of membrane characteristics between long-term operation and accelerated test
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Lee, Yong-Soo | - |
| dc.contributor.author | Kim, Wooha | - |
| dc.contributor.author | Kang, Hayoung | - |
| dc.contributor.author | Moon, Jiyoung | - |
| dc.contributor.author | Kim, Jong-Oh | - |
| dc.date.accessioned | 2021-07-30T05:10:25Z | - |
| dc.date.available | 2021-07-30T05:10:25Z | - |
| dc.date.issued | 2017-12 | - |
| dc.identifier.issn | 1944-3994 | - |
| dc.identifier.issn | 1944-3986 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/3442 | - |
| dc.description.abstract | In view of the maintenance and management, currently, there are insufficient diagnosis methods and guidelines of membrane filtration process applied in various water treatment facilities, which may judge the performance decrease due to the membrane property change. Despite the above situation, membrane has been continuously developed. Especially, since PVDF-material membrane, which is mostly applied nowadays, is hydrophobic, it tends to be conditioned by various additives. In this study, accelerated test was conducted for confirming the loss of C=O peak that affects the hydrophilicity, among the chemical structures of various additives, and filtration performance decrease. This study compares and evaluates the membrane property and performance between membrane of accelerated test and the membrane which is operated for long term of 3 years. In order to increase the reliability of accelerated test, attributable factors are enumerated. | - |
| dc.format.extent | 5 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Taylor & Francis | - |
| dc.title | Comparative evaluation of membrane characteristics between long-term operation and accelerated test | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.5004/dwt.2017.21644 | - |
| dc.identifier.scopusid | 2-s2.0-85042132241 | - |
| dc.identifier.wosid | 000425242300021 | - |
| dc.identifier.bibliographicCitation | Desalination and Water Treatment, v.99, pp 162 - 166 | - |
| dc.citation.title | Desalination and Water Treatment | - |
| dc.citation.volume | 99 | - |
| dc.citation.startPage | 162 | - |
| dc.citation.endPage | 166 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalResearchArea | Water Resources | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Chemical | - |
| dc.relation.journalWebOfScienceCategory | Water Resources | - |
| dc.subject.keywordPlus | SODIUM-HYPOCHLORITE | - |
| dc.subject.keywordPlus | PVDF MEMBRANE | - |
| dc.subject.keywordPlus | UF MEMBRANES | - |
| dc.subject.keywordPlus | PERFORMANCE | - |
| dc.subject.keywordPlus | SURFACE | - |
| dc.subject.keywordPlus | IMPACT | - |
| dc.subject.keywordAuthor | Membrane | - |
| dc.subject.keywordAuthor | Membrane properties | - |
| dc.subject.keywordAuthor | Accelerated test | - |
| dc.subject.keywordAuthor | Long-term operation | - |
| dc.identifier.url | https://www.deswater.com/vol.php?vol=99&oth=99|0|December|2017 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.