Cited 3 time in
Fixed volume sequential standard addition calibration: Value assignment of impurities in zero gas
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Brown, Richard J. C. | - |
| dc.contributor.author | Brewer, Paul J. | - |
| dc.contributor.author | Kim, Ki-Hyun | - |
| dc.date.accessioned | 2021-07-30T05:19:38Z | - |
| dc.date.available | 2021-07-30T05:19:38Z | - |
| dc.date.issued | 2017-05 | - |
| dc.identifier.issn | 0169-7439 | - |
| dc.identifier.issn | 1873-3239 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/4224 | - |
| dc.description.abstract | A fixed volume case of sequential standard addition calibration (S-SAC) for the value assignment of impurities in zero gas is described. A mathematical description of this technique has been derived and has been shown to exhibit a similar systematic bias during the extrapolation process to that seen for other S-SAC cases. The use of S-SAC in the gas phase has demonstrated that variation in the sample volume for S-SAC in the liquid phase is not the generalised cause of the bias experienced during extrapolation. Instead it is the variation in the volume of the original sample with respect to the overall volume of the mixture following the addition of standard. In addition, the requirement to perform a bias correction on the extrapolated values has been discussed and best practice solutions for correction proposed. | - |
| dc.format.extent | 4 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Elsevier BV | - |
| dc.title | Fixed volume sequential standard addition calibration: Value assignment of impurities in zero gas | - |
| dc.type | Article | - |
| dc.publisher.location | 네델란드 | - |
| dc.identifier.doi | 10.1016/j.chemolab.2017.03.012 | - |
| dc.identifier.scopusid | 2-s2.0-85016516268 | - |
| dc.identifier.wosid | 000400716100007 | - |
| dc.identifier.bibliographicCitation | Chemometrics and Intelligent Laboratory Systems, v.164, pp 52 - 55 | - |
| dc.citation.title | Chemometrics and Intelligent Laboratory Systems | - |
| dc.citation.volume | 164 | - |
| dc.citation.startPage | 52 | - |
| dc.citation.endPage | 55 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Automation & Control Systems | - |
| dc.relation.journalResearchArea | Chemistry | - |
| dc.relation.journalResearchArea | Computer Science | - |
| dc.relation.journalResearchArea | Instruments & Instrumentation | - |
| dc.relation.journalResearchArea | Mathematics | - |
| dc.relation.journalWebOfScienceCategory | Automation & Control Systems | - |
| dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
| dc.relation.journalWebOfScienceCategory | Computer Science, Artificial Intelligence | - |
| dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
| dc.relation.journalWebOfScienceCategory | Mathematics, Interdisciplinary Applications | - |
| dc.relation.journalWebOfScienceCategory | Statistics & Probability | - |
| dc.subject.keywordPlus | SYSTEMATIC-ERROR | - |
| dc.subject.keywordAuthor | standard addition | - |
| dc.subject.keywordAuthor | calibration | - |
| dc.subject.keywordAuthor | bias | - |
| dc.subject.keywordAuthor | zero gas | - |
| dc.subject.keywordAuthor | matrix | - |
| dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S0169743917300655?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.