Cited 69 time in
Graphene modified screen printed immunosensor for highly sensitive detection of parathion
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Mehta, Jyotsana | - |
| dc.contributor.author | Vinayak, Priya | - |
| dc.contributor.author | Tuteja, Satish K. | - |
| dc.contributor.author | Chhabra, Varun A. | - |
| dc.contributor.author | Bhardwaj, Neha | - |
| dc.contributor.author | Paul, Ashok Kumar | - |
| dc.contributor.author | Kim, Ki-Hyun | - |
| dc.contributor.author | Deep, Akash | - |
| dc.date.accessioned | 2021-07-30T05:28:08Z | - |
| dc.date.available | 2021-07-30T05:28:08Z | - |
| dc.date.issued | 2016-09 | - |
| dc.identifier.issn | 0956-5663 | - |
| dc.identifier.issn | 1873-4235 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/4972 | - |
| dc.description.abstract | Due to indiscriminate use of pesticides, there is a growing need to develop sensors that can sensitively detect the trace amount of pesticides in food and water samples. Parathion, identified as an acetylcholinesterase inhibitor, had been one of the most widely used pesticides throughout the world. Symptoms of its poisoning are found to be diverse enough to include nausea, vomiting, diarrhea, muscle cramping/twitching, and shortness of breath. In this work, a graphene based impedimetric immunosensor has been fabricated and employed for highly sensitive and specific detection of parathion. The fabrication proceeded through the modification of the screen-printed carbon electrodes (SPE) with graphene sheets, followed by their functionalization with 2-aminobenzyl amine (2-ABA) via an electrochemical reaction. These amine functionalized graphene electrodes were then bio-interfaced with the anti-parathion antibodies. In the impedimetric mode, this biosensor detected parathion in a broad linear range, i.e. 0.1-1000 ng/L with a very low limit of detection (52 pg/L). It also showed high selectivity towards parathion in the presence of malathion, paraoxon, and fenitrothion. The viability of this biosensor was demonstrated by detecting parathion in real samples (e.g., tomato and carrot) and through cross-calibration against HPLC. | - |
| dc.format.extent | 8 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Pergamon Press Ltd. | - |
| dc.title | Graphene modified screen printed immunosensor for highly sensitive detection of parathion | - |
| dc.type | Article | - |
| dc.publisher.location | 영국 | - |
| dc.identifier.doi | 10.1016/j.bios.2016.04.058 | - |
| dc.identifier.scopusid | 2-s2.0-84964527041 | - |
| dc.identifier.wosid | 000376802300048 | - |
| dc.identifier.bibliographicCitation | Biosensors and Bioelectronics, v.83, pp 339 - 346 | - |
| dc.citation.title | Biosensors and Bioelectronics | - |
| dc.citation.volume | 83 | - |
| dc.citation.startPage | 339 | - |
| dc.citation.endPage | 346 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Biophysics | - |
| dc.relation.journalResearchArea | Biotechnology & Applied Microbiology | - |
| dc.relation.journalResearchArea | Chemistry | - |
| dc.relation.journalResearchArea | Electrochemistry | - |
| dc.relation.journalResearchArea | Science & Technology - Other Topics | - |
| dc.relation.journalWebOfScienceCategory | Biophysics | - |
| dc.relation.journalWebOfScienceCategory | Biotechnology & Applied Microbiology | - |
| dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
| dc.relation.journalWebOfScienceCategory | Electrochemistry | - |
| dc.relation.journalWebOfScienceCategory | Nanoscience & Nanotechnology | - |
| dc.subject.keywordPlus | NANOPARTICLE-DECORATED GRAPHENE | - |
| dc.subject.keywordPlus | METAL-ORGANIC FRAMEWORK | - |
| dc.subject.keywordPlus | ELECTROCHEMICAL SENSOR | - |
| dc.subject.keywordPlus | ULTRASENSITIVE DETECTION | - |
| dc.subject.keywordPlus | ZIRCONIA NANOPARTICLES | - |
| dc.subject.keywordPlus | GOLD NANOPARTICLES | - |
| dc.subject.keywordPlus | OXIDE | - |
| dc.subject.keywordPlus | BIOSENSORS | - |
| dc.subject.keywordPlus | ACETYLCHOLINESTERASE | - |
| dc.subject.keywordPlus | ORGANOPHOSPHORUS | - |
| dc.subject.keywordAuthor | Graphene | - |
| dc.subject.keywordAuthor | Impedance | - |
| dc.subject.keywordAuthor | Parathion | - |
| dc.subject.keywordAuthor | Sensing | - |
| dc.subject.keywordAuthor | Screen-printed electrode | - |
| dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S0956566316303335?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.