Monte Carlo study of a compton camera: quantification of detector parameters affecting image quality

Full metadata record
DC Field Value Language
dc.contributor.author김찬형-
dc.date.accessioned2021-08-04T02:48:41Z-
dc.date.available2021-08-04T02:48:41Z-
dc.date.issued2006-08-27-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/69565-
dc.description.abstractThis study quantifies various parameters which affect the image quality (i.e., spatial resolution, signal-to-noise ratio, etc.) of a Compton camera by using the GEANT4 Monte Carlo particle simulation toolkits. This study considers F-18 radioisotope, which is popular in PET imaging and produces 511-keV annihilation photons. The Compton camera modeled in this study is composed of a scatterer (a double-sided silicon strip detector, 5 x 5 x 0.15 cm3) and an absorber (a 25-segmented germanium detector, 5 x 5 x 2 cm3) and these detectors are separated by 5 cm. The F-18 radioisotope (point source) is assumed to be located at 6 cm in front of the scatterer. This study modeled the Compton camera realistically including all the details of the Compton camera. The PENELOPE physics model was used to include the effects of atomic binding and Doppler energy broadening in Compton scattering. The discrimination level of the Compton camera was also modeled for the scatterer and absorber (i.e., 15 keV and 50 keV, respectively). This study modeled the resolution of the detectors by assuming the Gaussian distribution of the energy peak. Our result shows that the segmentation of the absorber, which is a 25-segmenterd germanium detector (5 x 5 x 2 cm3), significantly degrades the resolution of the Compton camera (FWHM = 1.6 cm). The Doppler broadening and detector energy resolution slightly lower the resolution of the Compton camera (i.e., FWHM of 0.328 cm and 0.130 cm, respectively). The image quality is also slightly affected by the detector discrimination level.-
dc.titleMonte Carlo study of a compton camera: quantification of detector parameters affecting image quality-
dc.typeConference-
dc.citation.conferenceNameWorld Congress on Medical Physics and Biomedical Engineering 2006-
dc.citation.conferencePlaceSeoul, Korea-
Files in This Item
There are no files associated with this item.
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 2. Conference Papers

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE