Detailed Information

Cited 2 time in webofscience Cited 3 time in scopus
Metadata Downloads

Dose coefficients of mesh-type ICRP reference computational phantoms for external exposures of neutrons, protons, and helium ions

Full metadata record
DC Field Value Language
dc.contributor.authorYeom, Yeon Soo-
dc.contributor.authorChoi, Chansoo-
dc.contributor.authorHan, Haegin-
dc.contributor.authorShin, Bangho-
dc.contributor.authorNguyen, Thang Tat-
dc.contributor.authorHan, Min Cheol-
dc.contributor.authorKim, Chan Hyeong-
dc.contributor.authorLee, Choonsik-
dc.date.accessioned2021-08-02T09:26:18Z-
dc.date.available2021-08-02T09:26:18Z-
dc.date.created2021-05-11-
dc.date.issued2020-07-
dc.identifier.issn1738-5733-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/9700-
dc.description.abstractRecently, the International Commission on Radiological Protection (ICRP) has developed the Mesh-type Reference Computational Phantoms (MRCPs) for adult male and female to overcome the limitations of the current Voxel-type Reference Computational Phantoms (VRCPs) described in ICRP Publication 110 due to the limited voxel resolutions and the nature of voxel geometry. In our previous study, the MRCPs were used to calculate the dose coefficients (DCs) for idealized external exposures of photons and electrons. The present study is an extension of the previous study to include three additional particles (i.e., neutrons, protons, and helium ions) into the DC library by conducting Monte Carlo radiation transport simulations with the Geant4 code. The calculated MRCP DCs were compared with the reference DCs of ICRP Publication 116 which are based on the VRCPs, to appreciate the impact of the new reference phantoms on the DC values. We found that the MRCP DCs of organ/tissue doses and effective doses were generally similar to the ICRP-116 DCs for neutrons, whereas there were significant DC differences up to several orders of magnitude for protons and helium ions due mainly to the improved representation of the detailed anatomical structures in the MRCPs over the VRCPs.-
dc.language영어-
dc.language.isoen-
dc.publisherKOREAN NUCLEAR SOC-
dc.titleDose coefficients of mesh-type ICRP reference computational phantoms for external exposures of neutrons, protons, and helium ions-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Chan Hyeong-
dc.identifier.doi10.1016/j.net.2019.12.020-
dc.identifier.scopusid2-s2.0-85077147791-
dc.identifier.wosid000541484900024-
dc.identifier.bibliographicCitationNUCLEAR ENGINEERING AND TECHNOLOGY, v.52, no.7, pp.1545 - 1556-
dc.relation.isPartOfNUCLEAR ENGINEERING AND TECHNOLOGY-
dc.citation.titleNUCLEAR ENGINEERING AND TECHNOLOGY-
dc.citation.volume52-
dc.citation.number7-
dc.citation.startPage1545-
dc.citation.endPage1556-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART002602847-
dc.description.journalClass1-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.subject.keywordPlusPROTECTION-
dc.subject.keywordAuthorICRP reference phantom-
dc.subject.keywordAuthorMesh-
dc.subject.keywordAuthorDose coefficient-
dc.subject.keywordAuthorNeutrons-
dc.subject.keywordAuthorProtons-
dc.subject.keywordAuthorHelium ions-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S1738573319309726?via%3Dihub-
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE