Integrity assessment of obsolete thermal storage tank in district heating system

Full metadata record
DC Field Value Language
dc.contributor.authorYun-
dc.contributor.authorD.-
dc.contributor.authorChae-
dc.contributor.authorH.-
dc.contributor.authorKim, Heesan-
dc.contributor.authorH.-
dc.contributor.authorKim-
dc.contributor.authorJ.-G.-
dc.contributor.authorKim-
dc.contributor.authorW.C.-
dc.contributor.authorHa-
dc.contributor.authorT.B.-
dc.contributor.authorJang-
dc.contributor.authorJ.-
dc.contributor.authorJeong-
dc.contributor.authorJ.C.-
dc.contributor.authorLee-
dc.contributor.authorS.Y.-
dc.date.available2021-03-17T07:48:15Z-
dc.date.created2021-02-26-
dc.date.issued2020-
dc.identifier.issn1738-8228-
dc.identifier.urihttps://scholarworks.bwise.kr/hongik/handle/2020.sw.hongik/12528-
dc.description.abstractThe thermal storage tank in a district heating system is a component that stores excess heat during normal operation and releases the stored heat to increase the efficiency of the system, when the heat source is stopped or additional demands occur. Recently, an obsolete thermal storage tank was dismantled for the first time since it began operation 30 years ago. In this work, the corrosion integrity of the obsolete thermal storage tank was evaluated by examining its appearance, thickness thinning, corrosion products, microstructure, and mechanical properties. Samples were taken at various locations (roof, shell, bottom) of the thermal storage tank, which enabled diagnosis of the respective environmental degradations. Severe corrosion was found in the roof edge plate due to corrosion under the insulation, and exhibited thinning exceeding ~49% of the designed thickness. In this location, the ferrite-pearlite band structure disappeared and deteriorated microstructures, such as decarburization and spheroidized pearlite, were measured, which resulted in a ~27% decrease in hardness. The inner surfaces of the bottom and shell plate were well covered with a magnetite film, and the degradation of the microstructure and mechanical properties showed a permissible limit in terms of ASTM A285/ A516. In addition, no particular drop in hardness was found in the weld zone of each plate. Copyright © The Korean Institute of Metals and Materials-
dc.publisherKorean Institute of Metals and Materials-
dc.titleIntegrity assessment of obsolete thermal storage tank in district heating system-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Heesan-
dc.identifier.doi10.3365/KJMM.2020.58.10.693-
dc.identifier.scopusid2-s2.0-85092790991-
dc.identifier.bibliographicCitationJournal of Korean Institute of Metals and Materials, v.58, no.10, pp.693 - 702-
dc.relation.isPartOfJournal of Korean Institute of Metals and Materials-
dc.citation.titleJournal of Korean Institute of Metals and Materials-
dc.citation.volume58-
dc.citation.number10-
dc.citation.startPage693-
dc.citation.endPage702-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscopus-
dc.subject.keywordAuthorCorrosion-
dc.subject.keywordAuthorDegradation-
dc.subject.keywordAuthorDistrict heating system-
dc.subject.keywordAuthorStructural integrity-
dc.subject.keywordAuthorThermal storage tank-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hee san photo

Kim, Hee san
Science & Technology (Department of Nanomaterials Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE