Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

집적광학 바이오케미컬 센서에 적합한 Si3N4/SiO2 슬롯 및 릿지-슬롯 광 도파로 제원 최적화 및 감지도 해석

Full metadata record
DC Field Value Language
dc.contributor.author장재식-
dc.contributor.author정홍식-
dc.date.accessioned2021-09-02T02:43:48Z-
dc.date.available2021-09-02T02:43:48Z-
dc.date.created2021-08-18-
dc.date.issued2021-
dc.identifier.issn1225-5475-
dc.identifier.urihttps://scholarworks.bwise.kr/hongik/handle/2020.sw.hongik/15691-
dc.description.abstractNumerical analysis was performed using FIMMWAVE to optimize the specifications of Si3N4/SiO2 slot and ridge-slot optical waveguides based on confinement factor and effective mode area. The optimized specifications were confirmed based on sensitivity in terms of the refractive index of the analyte. The specifications of the slot optical waveguide, i.e., the width of the slot and the width and height of the rails, were optimized to 0.2 µm, 0.46 µm, and 0.5 µm, respectively. When the wavelength was 1.55 µm and the refractive index of the slot was 1.3, the confinement factor and effective mode area of 0.2024 and 2.04µm2 , respectively, were obtained based on the optimized specifications. The thickness of the ridge and the refractive index of the slot were set to 0.04 µm and 1.1, respectively, to optimize the ridge-slot optical waveguide, and the confinement factor and effective mode area were calculated as 0.1393 and 2.90 µm2 , respectively. When the confinement coefficient and detection degree of the two structures were compared in the range of 1 to 1.3 of the analyte index, it was observed that the confinement coefficient and sensitivity were higher in the ridge-slot optical waveguide in the region with a refractive index less than 1.133, but the reverse situation occurred in the other region. Therefore, in the implementation of the integrated optical biochemical sensor, it is possible to propose a selection criterion for the two parameters depending on the value of the refractive index of the analyte.-
dc.language한국어-
dc.language.isoko-
dc.publisher한국센서학회-
dc.title집적광학 바이오케미컬 센서에 적합한 Si3N4/SiO2 슬롯 및 릿지-슬롯 광 도파로 제원 최적화 및 감지도 해석-
dc.title.alternativeSpecification optimization and sensitivity analysis of Si3N4/SiO2 slot and ridge-slot optical waveguides for integrated-optical biochemical sensors-
dc.typeArticle-
dc.contributor.affiliatedAuthor정홍식-
dc.identifier.bibliographicCitation센서학회지, v.30, no.3, pp.139 - 147-
dc.relation.isPartOf센서학회지-
dc.citation.title센서학회지-
dc.citation.volume30-
dc.citation.number3-
dc.citation.startPage139-
dc.citation.endPage147-
dc.type.rimsART-
dc.identifier.kciidART002722401-
dc.description.journalClass2-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorSlot waveguide-
dc.subject.keywordAuthorRidge-slot waveguide-
dc.subject.keywordAuthorIntegrated-optical sensor-
dc.subject.keywordAuthorConfinement factor-
dc.subject.keywordAuthorEffective mode area-
dc.subject.keywordAuthorSensitivity-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Science and Technology > Department of Electronic and Electrical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jung, Hong sik photo

Jung, Hong sik
Science & Technology (Department of Electronic & Electrical Convergence Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE