Four-Switch 인버터의 전압 변동 보상 기법을 통한 전동기 운전 기법Motor Control Method for Four-Switch Inverters with DC-link Voltage Ripple Compensation Algorithm
- Other Titles
- Motor Control Method for Four-Switch Inverters with DC-link Voltage Ripple Compensation Algorithm
- Authors
- 이동명
- Issue Date
- 2013
- Publisher
- 한국조명.전기설비학회
- Keywords
- Four-Switch Inverter; DC-Link Voltage Ripple; Fault Redundancy; Split DC-Link
- Citation
- 조명.전기설비학회논문지, v.27, no.7, pp.59 - 66
- Journal Title
- 조명.전기설비학회논문지
- Volume
- 27
- Number
- 7
- Start Page
- 59
- End Page
- 66
- URI
- https://scholarworks.bwise.kr/hongik/handle/2020.sw.hongik/17731
- ISSN
- 1229-4691
- Abstract
- This paper proposes a new voltage reference generation method for Four-Switch Inverters(FSI) with compensation of the neutral DC-link voltage variation. Since FSIs have the split DC-link causing the inherent problem of voltage fluctuations in the upper and lower capacitors, it is required to take account the voltage difference between the top and bottom capacitors. In this paper, to reduce the effect by the voltage variation, reference voltages are modified by adding compensation voltages proportional to the voltage difference between upper and lower capacitors. Simulation results showing control performance of induction and permanent magnet motors demonstrate the validity of the proposed method.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Engineering > School of Electronic & Electrical Engineering > 1. Journal Articles
![qrcode](https://api.qrserver.com/v1/create-qr-code/?size=55x55&data=https://scholarworks.bwise.kr/hongik/handle/2020.sw.hongik/17731)
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.