Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Four-Switch 인버터의 전압 변동 보상 기법을 통한 전동기 운전 기법Motor Control Method for Four-Switch Inverters with DC-link Voltage Ripple Compensation Algorithm

Other Titles
Motor Control Method for Four-Switch Inverters with DC-link Voltage Ripple Compensation Algorithm
Authors
이동명
Issue Date
2013
Publisher
한국조명.전기설비학회
Keywords
Four-Switch Inverter; DC-Link Voltage Ripple; Fault Redundancy; Split DC-Link
Citation
조명.전기설비학회논문지, v.27, no.7, pp.59 - 66
Journal Title
조명.전기설비학회논문지
Volume
27
Number
7
Start Page
59
End Page
66
URI
https://scholarworks.bwise.kr/hongik/handle/2020.sw.hongik/17731
ISSN
1229-4691
Abstract
This paper proposes a new voltage reference generation method for Four-Switch Inverters(FSI) with compensation of the neutral DC-link voltage variation. Since FSIs have the split DC-link causing the inherent problem of voltage fluctuations in the upper and lower capacitors, it is required to take account the voltage difference between the top and bottom capacitors. In this paper, to reduce the effect by the voltage variation, reference voltages are modified by adding compensation voltages proportional to the voltage difference between upper and lower capacitors. Simulation results showing control performance of induction and permanent magnet motors demonstrate the validity of the proposed method.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Electronic & Electrical Engineering > 1. Journal Articles