Energy Performance and Improvement in University Library - Concentrated on ‘K’University Library located in Seojong City -
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 노지웅 | - |
dc.date.accessioned | 2021-11-25T03:43:25Z | - |
dc.date.available | 2021-11-25T03:43:25Z | - |
dc.date.created | 2021-11-23 | - |
dc.date.issued | 2014 | - |
dc.identifier.issn | 2288-968X | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hongik/handle/2020.sw.hongik/18436 | - |
dc.description.abstract | The problem of energy consumption is more serious in university buildings than primary, middle and high school buildings. Because university buildings have generally heating and cooling systems, and various incidental facilities. In university, the library is one of the building that many people use and the most energy is spent. So, investigation on energy saving is very important and urgent. This study aims finally to present the guideline for low-energy design of University library by aiding a designer to select best solution in the side of energy-saving. In this paper, composition of space, utilization schedule and performance of construction materials are grasped, some primary factors that effect to energy saving are analyzed by energy simulation. The result of this study is as follows;First, the subject library has more cooling load than heating load because of cooling load generated during middle season. Second, green roofs is the most effective to heating load saving, but not to cooling energy. Third, outdoor air cooling is the most effective to cooling energy saving among the investigated strategies included in this study. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | 한국생태환경건축학회 | - |
dc.title | Energy Performance and Improvement in University Library - Concentrated on ‘K’University Library located in Seojong City - | - |
dc.title.alternative | Energy Performance and Improvement in University Library - Concentrated on ‘K’University Library located in Seojong City - | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 노지웅 | - |
dc.identifier.doi | 10.12813/kieae.2014.14.4.047 | - |
dc.identifier.bibliographicCitation | KIEAE Journal, v.14, no.4, pp.47 - 52 | - |
dc.relation.isPartOf | KIEAE Journal | - |
dc.citation.title | KIEAE Journal | - |
dc.citation.volume | 14 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 47 | - |
dc.citation.endPage | 52 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART001906964 | - |
dc.description.journalClass | 2 | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | University library | - |
dc.subject.keywordAuthor | Energy saving | - |
dc.subject.keywordAuthor | Utilization schedule | - |
dc.subject.keywordAuthor | Energy simulation | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
94, Wausan-ro, Mapo-gu, Seoul, 04066, Korea02-320-1314
COPYRIGHT 2020 HONGIK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.