냉복도 밀폐시스템의 적용에 의한 데이터센터 서버실의 냉방에너지 절감 효과 분석

Full metadata record
DC Field Value Language
dc.contributor.author장현재-
dc.contributor.author정용호-
dc.contributor.author서장후-
dc.date.accessioned2021-12-02T05:43:36Z-
dc.date.available2021-12-02T05:43:36Z-
dc.date.created2021-11-29-
dc.date.issued2012-
dc.identifier.issn1976-6483-
dc.identifier.urihttps://scholarworks.bwise.kr/hongik/handle/2020.sw.hongik/19353-
dc.description.abstractIn order to keep the server room temperature condition, energy consumption has been rapidly increased as the increasing internal heat gain of server room in data center. And the cooling units for server systems are fully operated to satisfy the indoor temperature condition, it results in the excessive energy consumption. There are many wastes of cooling energy which is caused by the structural problems in data center server room. For example, a leakage by the electric cable hole, mixing or recirculation of hot air from the hot aisle to the cold aisle, short circulation of the CRAC(Computer Room Air Conditioning), and others. So there are many strategies to reduce the waste of cooling energy in data center. In this study, cold aisle containment system was proposed among the various strategies to reduce the waste energy by recirculation air from the hot aisle. To verify the effectiveness of the cold aisle containment system, test bed which is same with exist server room was set up in IDC(Internet Data Center) building. And comparative experiments, conventional open type cooling system and cold aisle containment sysetm, were carried out in actual conditions. As the result, the range of inlet temperature of server system was 20~25℃ in exist cooling system and the range of inlet temperature dropped below 20℃ by cold aisle containment system. After all, was possible by the cold aisle containment system and cold aisle containment system was proved to be the solution for energy saving cooling system.-
dc.language한국어-
dc.language.isoko-
dc.publisher한국건축친환경설비학회-
dc.title냉복도 밀폐시스템의 적용에 의한 데이터센터 서버실의 냉방에너지 절감 효과 분석-
dc.title.alternativeAnalysis of Cooling Energy Saving by Cold Aisle Containment System in Internet Data Center Server Room-
dc.typeArticle-
dc.contributor.affiliatedAuthor장현재-
dc.identifier.bibliographicCitation한국건축친환경설비학회 논문집, v.6, no.3, pp.181 - 190-
dc.relation.isPartOf한국건축친환경설비학회 논문집-
dc.citation.title한국건축친환경설비학회 논문집-
dc.citation.volume6-
dc.citation.number3-
dc.citation.startPage181-
dc.citation.endPage190-
dc.type.rimsART-
dc.identifier.kciidART001700568-
dc.description.journalClass2-
dc.description.journalRegisteredClasskci-
dc.description.journalRegisteredClassother-
dc.subject.keywordAuthorCRAC-
dc.subject.keywordAuthorData center-
dc.subject.keywordAuthorEnergy cost-
dc.subject.keywordAuthorCold aisle containment system-
dc.subject.keywordAuthorRe-circulation air-
dc.subject.keywordAuthorCold aisle-
dc.subject.keywordAuthor항온항습기-
dc.subject.keywordAuthor데이터 센터-
dc.subject.keywordAuthor에너지 비용-
dc.subject.keywordAuthor밀폐형 쿨링시스템-
dc.subject.keywordAuthor재순환공기-
dc.subject.keywordAuthor냉복도-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Science and Technology > Major in Architecture Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chang, Hyun jae photo

Chang, Hyun jae
Science & Technology (Architectural Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE