Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

적응 대역필터를 이용한 의료 초음파 감쇠 예측Estimation of Medical Ultrasound Attenuation using Adaptive Bandpass Filters

Other Titles
Estimation of Medical Ultrasound Attenuation using Adaptive Bandpass Filters
Authors
허서원이준환김형석
Issue Date
2010
Publisher
대한전자공학회
Keywords
medical ultrasound; attenuation; VSA method; bandpass filter; quantitative ultrasound analysis
Citation
전자공학회논문지 - SC, v.47, no.5, pp.43 - 51
Journal Title
전자공학회논문지 - SC
Volume
47
Number
5
Start Page
43
End Page
51
URI
https://scholarworks.bwise.kr/hongik/handle/2020.sw.hongik/21163
ISSN
1229-6392
Abstract
Attenuation coefficients of medical ultrasound not only reflect the pathological information of tissues scanned but also provide the quantitative information to compensate the decay of backscattered signals for other medical ultrasound parameters. Based on the frequency-selective attenuation property of human tissues, attenuation estimation methods in spectral domain have difficulties for real-time implementation due to the complexicity while estimation methods in time domain do not achieve the compensation for the diffraction effect effectively. In this paper, we propose the modified VSA method, which compensates the diffraction with reference phantom in time domain, using adaptive bandpass filters with decreasing center frequencies along depths. The adaptive bandpass filtering technique minimizes the distortion of relative echogenicity of wideband transmit pulses and maximizes the signal-to-noise ratio due to the random scattering, especially at deeper depths. Since the filtering center frequencies change according to the accumulated attenuation, the proposed algorithm improves estimation accuracy and precision comparing to the fixed filtering method. Computer simulation and experimental results using tissue-mimicking phantoms demonstrate that the distortion of relative echogenicity is decreased at deeper depths, and the accuracy of attenuation estimation is improved by 5.1% and the standard deviation is decreased by 46.9% for the entire scan depth.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Electronic & Electrical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Heo, Seo Weon photo

Heo, Seo Weon
Engineering (Electronic & Electrical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE