콘크리트 충전 FRP 원통관의 압축거동에 관한 실험적 연구

Full metadata record
DC Field Value Language
dc.contributor.author주형중-
dc.contributor.author이승식-
dc.contributor.author김영호-
dc.contributor.author박종화-
dc.contributor.author윤순종-
dc.date.accessioned2022-01-13T07:44:09Z-
dc.date.available2022-01-13T07:44:09Z-
dc.date.created2022-01-04-
dc.date.issued2008-
dc.identifier.issn2288-2103-
dc.identifier.urihttps://scholarworks.bwise.kr/hongik/handle/2020.sw.hongik/23128-
dc.description.abstractDurability problems may arise in the concrete, which is one of the major construction materials, used in the construction field. Bridge piers and foundation piles are usually made with concrete and they are exposed to the moisture and hence the durability of the concrete reduced significantly due to oxidization of re-bar and icing of concrete. To mitigate such problems, FRP tube has been developed and the concrete filled FRP tube (CFFT) has been investigated to find the confinement effect which is provided additionally. It was reported that if the concrete is wrapped with FRP, strength and chemical resistance are improved significantly. In order to apply such a member in the construction field, structural behavior and applicable design guideline or design criteria must be thoroughly investigated. In the experimental investigation, the results are compared with the previous research results and the relationship which can predict the ultimate strength and strain is suggested. In addition, some comments found at the compression tests are given briefly.-
dc.language한국어-
dc.language.isoko-
dc.publisher한국복합재료학회-
dc.title콘크리트 충전 FRP 원통관의 압축거동에 관한 실험적 연구-
dc.title.alternativeExperimental Investigation on the Compression Behavior of Concrete Filled Circular FRP Tubes-
dc.typeArticle-
dc.contributor.affiliatedAuthor윤순종-
dc.identifier.bibliographicCitationComposites Research, v.21, no.3, pp.24 - 30-
dc.relation.isPartOfComposites Research-
dc.citation.titleComposites Research-
dc.citation.volume21-
dc.citation.number3-
dc.citation.startPage24-
dc.citation.endPage30-
dc.type.rimsART-
dc.identifier.kciidART001259842-
dc.description.journalClass2-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthor콘크리트 충전 FRP 원통관-
dc.subject.keywordAuthorConcrete Filled Circular FRP Tube-
dc.subject.keywordAuthorCFFT-
dc.subject.keywordAuthor구속효과-
dc.subject.keywordAuthorConfining Effect-
dc.subject.keywordAuthor일축압축실험-
dc.subject.keywordAuthorUniaxial Compression Test-
dc.subject.keywordAuthor압축거동-
dc.subject.keywordAuthorCompression Behavior-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Civil Engineering Major > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE