dc.description.abstract | Since of its aesthetic advantage, the shape of apartment houses has shifted from liner types toward the towers. Though they have advantages in terms of aesthetic in modern architecture, however, rectangular-shaped towers causes being short of natural light due to deep interior space. There are compromised attempts to take advantages of each building shape selectively. As a result, we now witness the advent of Y-shaped, T-shaped, V-shaped and ㅈ-shaped buildings on the market. The mutative type of apartment houses usually faces southwest or southeast, which has lot of daylighting availability but anyhow, the proportion of the apartment houses which have a full south aspect. The need to verify the potential of daylighting in new building-block shapes exists. At the same time, the expansion of balcony area was legalized and thus, a visual buffer area does not exist any more. All-glass window wall on apartment houses without a balcony produces pretty harmful area with direct sunbeam. Recently, the refurbished version of conventional windows has been developed for the purposed of minimizing energy loss occurred around windows. This research initialized a series of research to deal with almost all on window wall for apartment houses. First of all, huge amount of already-designed examples of apartment houses have been analyzed in terms of floor plan, elevation, orientation and glazing materials. | - |
dc.language | 한국어 | - |
dc.language.iso | ko | - |
dc.publisher | 한국생태환경건축학회 | - |
dc.title | 공동주택의 배치유형에 따른 창호 시스템의 채광특성 | - |
dc.title.alternative | Daylighting Performance of Refurbished Window System based on Site Plans in Recently-Planned Apartment Houses | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 노지웅 | - |
dc.identifier.bibliographicCitation | KIEAE Journal, v.8, no.1, pp.37 - 44 | - |
dc.relation.isPartOf | KIEAE Journal | - |
dc.citation.title | KIEAE Journal | - |
dc.citation.volume | 8 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 37 | - |
dc.citation.endPage | 44 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART001247247 | - |
dc.description.journalClass | 2 | - |
dc.description.journalRegisteredClass | kci | - |
dc.description.journalRegisteredClass | other | - |
dc.subject.keywordAuthor | 방위각 | - |
dc.subject.keywordAuthor | 배치계획 | - |
dc.subject.keywordAuthor | 투과체 | - |
dc.subject.keywordAuthor | 투과율 | - |
dc.subject.keywordAuthor | 채광성능 | - |
dc.subject.keywordAuthor | azimuth angle | - |
dc.subject.keywordAuthor | site plan | - |
dc.subject.keywordAuthor | variable glazing | - |
dc.subject.keywordAuthor | transmittance | - |
dc.subject.keywordAuthor | daylighting performance | - |
dc.subject.keywordAuthor | azimuth angle | - |
dc.subject.keywordAuthor | site plan | - |
dc.subject.keywordAuthor | variable glazing | - |
dc.subject.keywordAuthor | transmittance | - |
dc.subject.keywordAuthor | daylighting performance | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
94, Wausan-ro, Mapo-gu, Seoul, 04066, Korea02-320-1314
COPYRIGHT 2020 HONGIK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.