Development of an animal experimental model for a bileaflet mechanical heart valve prosthesis
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Choo, SJ | - |
dc.contributor.author | Kim, KI | - |
dc.contributor.author | Park, NH | - |
dc.contributor.author | Song, JM | - |
dc.contributor.author | Choi, IC | - |
dc.contributor.author | Shim, JY | - |
dc.contributor.author | Lee, SK | - |
dc.contributor.author | Kwon, YJ | - |
dc.contributor.author | Kim, CN | - |
dc.contributor.author | Lee, JW | - |
dc.date.accessioned | 2022-02-18T07:42:19Z | - |
dc.date.available | 2022-02-18T07:42:19Z | - |
dc.date.created | 2022-02-18 | - |
dc.date.issued | 2004-02 | - |
dc.identifier.issn | 1011-8934 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hongik/handle/2020.sw.hongik/25796 | - |
dc.description.abstract | The objective of this study was to develop a pre-clinical large animal model for the in vivo hemodynamic testing of prosthetic valves in the aortic position without the need for cardiopulmonary bypass. Ten male pigs were used. A composite valved conduit was constructed in the operating room by implanting a prosthetic valve between two separate pieces of vascular conduits, which bypassed the ascending aorta to the descending aorta. Prior to applying a side-biting clamp to the ascending aorta for proximal grafting to the aortic anastomosis, an aorta to femoral artery shunt was placed just proximally to this clamp. The heart rate, cardiac output, V-max, transvalvular pressure gradient, effective orifice area and incremental dobutamine stress response were assessed. A dose dependant increase with dobutamine was seen in terms of cardiac output, V-max, and the peak transvalvular pressure gradient both in the native and in the prosthetic valve. However the increment, was much steeper in the prosthetic valve. No significant differences in cardiac output were noted between the native and the prosthetic valves. The described pre-clinical porcine model was found suitable for site-specific in-vivo hemodynamic assessment of aortic valvular prosthesis without cardiopulmonary bypass. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | KOREAN ACAD MEDICAL SCIENCES | - |
dc.subject | JUVENILE SHEEP | - |
dc.subject | AORTIC VALVES | - |
dc.subject | PIGS | - |
dc.subject | IMPLANTATION | - |
dc.subject | EXPERIENCE | - |
dc.subject | SAFETY | - |
dc.title | Development of an animal experimental model for a bileaflet mechanical heart valve prosthesis | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kwon, YJ | - |
dc.identifier.doi | 10.3346/jkms.2004.19.1.37 | - |
dc.identifier.scopusid | 2-s2.0-10744229733 | - |
dc.identifier.wosid | 000189325700007 | - |
dc.identifier.bibliographicCitation | JOURNAL OF KOREAN MEDICAL SCIENCE, v.19, no.1, pp.37 - 41 | - |
dc.relation.isPartOf | JOURNAL OF KOREAN MEDICAL SCIENCE | - |
dc.citation.title | JOURNAL OF KOREAN MEDICAL SCIENCE | - |
dc.citation.volume | 19 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 37 | - |
dc.citation.endPage | 41 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.relation.journalResearchArea | General & Internal Medicine | - |
dc.relation.journalWebOfScienceCategory | Medicine, General & Internal | - |
dc.subject.keywordPlus | JUVENILE SHEEP | - |
dc.subject.keywordPlus | AORTIC VALVES | - |
dc.subject.keywordPlus | PIGS | - |
dc.subject.keywordPlus | IMPLANTATION | - |
dc.subject.keywordPlus | EXPERIENCE | - |
dc.subject.keywordPlus | SAFETY | - |
dc.subject.keywordAuthor | surgical instruments | - |
dc.subject.keywordAuthor | prosthetic valve | - |
dc.subject.keywordAuthor | cardiopulmonary bypass | - |
dc.subject.keywordAuthor | hemodynamic assessment | - |
dc.subject.keywordAuthor | hemodynamic processes | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
94, Wausan-ro, Mapo-gu, Seoul, 04066, Korea02-320-1314
COPYRIGHT 2020 HONGIK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.