Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Active Damping of LCL Filter without Capacitor Voltage Sensors for Three Phase PWM Inverter

Authors
An, Byoung-WoongKim, Hag-WoneCho, Kwan-YuhlHan, Byung-MoonChung, Gyo-Bum
Issue Date
2013
Publisher
IEEE
Keywords
SVPWM Inverter; Active damping; MRAS(Model Reference Adaptive System) Observer; LCL filter
Citation
39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), pp.7129 - 7133
Journal Title
39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013)
Start Page
7129
End Page
7133
URI
https://scholarworks.bwise.kr/hongik/handle/2020.sw.hongik/29593
ISSN
1553-572X
Abstract
In this paper, new sensorless active damping method of the grid-connected LCL filter for a three-phase PWM inverter is proposed. The resonance component of capacitor voltage of LCL filter is observed by a simple MRAS (Model Reference Adaptive System) observer without additional sensors or circuits. The active damping is implemented by feed-forward compensation of the observed capacitor voltage for current controller. The validity of the proposed method is verified by the simulation and experiment.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Science and Technology > Department of Electronic and Electrical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chung, Gyo Bum photo

Chung, Gyo Bum
Science & Technology (Department of Electronic & Electrical Convergence Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE