A Case Study on the Verification of Passive Office Energy Performance Comparing Actual Energy Consumption to Simulation Result
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ko, Young Sun | - |
dc.contributor.author | No, Sang Tae | - |
dc.date.accessioned | 2022-06-20T00:41:22Z | - |
dc.date.available | 2022-06-20T00:41:22Z | - |
dc.date.created | 2022-06-20 | - |
dc.date.issued | 2013 | - |
dc.identifier.issn | 1660-9336 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hongik/handle/2020.sw.hongik/29600 | - |
dc.description.abstract | The objective of this study is to verify energy performance of passive office building compared to existing building using computer simulation tool, EnergyPlus. S building was selected as a passive office building, which is the first passive office building in KOREA, and the building satisfy the passive house standard. The annual energy consumption data were compared to the heating and cooling load result of EnergyPlus, to verify simulation accuracy. The conditions of existing building were selected from Korean envelope standard and the categories of the conditions are the insulation thickness and glazing composition. As a result, the passive office showed 28% reduced energy consumption, compared to the existing building, with ordinary envelope under Korean building envelope standard. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | TRANS TECH PUBLICATIONS LTD | - |
dc.title | A Case Study on the Verification of Passive Office Energy Performance Comparing Actual Energy Consumption to Simulation Result | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Ko, Young Sun | - |
dc.identifier.doi | 10.4028/www.scientific.net/AMM.361-363.427 | - |
dc.identifier.wosid | 000329536600086 | - |
dc.identifier.bibliographicCitation | SUSTAINABLE CITIES DEVELOPMENT AND ENVIRONMENT PROTECTION, PTS 1-3, v.361-363, pp.427 - + | - |
dc.relation.isPartOf | SUSTAINABLE CITIES DEVELOPMENT AND ENVIRONMENT PROTECTION, PTS 1-3 | - |
dc.citation.title | SUSTAINABLE CITIES DEVELOPMENT AND ENVIRONMENT PROTECTION, PTS 1-3 | - |
dc.citation.volume | 361-363 | - |
dc.citation.startPage | 427 | - |
dc.citation.endPage | + | - |
dc.type.rims | ART | - |
dc.type.docType | Proceedings Paper | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Construction & Building Technology | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalWebOfScienceCategory | Construction & Building Technology | - |
dc.relation.journalWebOfScienceCategory | Engineering, Environmental | - |
dc.relation.journalWebOfScienceCategory | Engineering, Civil | - |
dc.subject.keywordAuthor | Passive Office | - |
dc.subject.keywordAuthor | EnergyPlus | - |
dc.subject.keywordAuthor | Insulation | - |
dc.subject.keywordAuthor | Glazing | - |
dc.subject.keywordAuthor | Heating and Cooling Load | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
94, Wausan-ro, Mapo-gu, Seoul, 04066, Korea02-320-1314
COPYRIGHT 2020 HONGIK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.