Enhancing indoor building occupant safety in the built environment: Assessing the validity of social force modeling for simulating physical distancing behaviors

Full metadata record
DC Field Value Language
dc.contributor.authorYoon, Inseok-
dc.contributor.authorAhn, Changbum-
dc.contributor.authorAhn, Seungjun-
dc.contributor.authorLee, Bogyeong-
dc.contributor.authorLee, Jongjik-
dc.contributor.authorPark, Moonseo-
dc.date.accessioned2024-03-06T09:30:21Z-
dc.date.available2024-03-06T09:30:21Z-
dc.date.issued2024-03-
dc.identifier.issn2666-1659-
dc.identifier.issn2666-1659-
dc.identifier.urihttps://scholarworks.bwise.kr/hongik/handle/2020.sw.hongik/32716-
dc.description.abstractFacility managers play a key role in ensuring the safety of occupants in indoor environments, particularly in the event of a disaster. Pedestrian Simulation Models, such as the Social Force Model (SFM), are essential for simulating pedestrian behavior and evaluating safety measures in complex indoor environments. These models help to identify potential hazards and bottlenecks. However, concerns about the accuracy of the SFM in reproducing physical distance, particularly during the COVID-19 pandemic, have raised doubts about its reliability, but little attention has been paid to the validity of the SFM in analyzing human movement in indoor environments. Our study rigorously evaluates the applicability of SFM for simulating physical distancing behavior in indoor environments, using trajectory data from building occupants during the COVID-19 peak. The investigation compares standard SFM with Pandemic SFM, which is customized for physical distancing. The results clearly demonstrate the superior performance of Pandemic-SFM in replicating indoor occupant movement, particularly in crowded spaces. Sensitivity analysis highlights the importance of accurately modeling physical distancing, particularly during infectious disease outbreaks. These findings hold great promise for improving occupant behavior simulation models, especially in indoor building environments, and provide scientific evidence to guide safety improvements during pandemics. © 2024-
dc.language영어-
dc.language.isoENG-
dc.publisherElsevier Ltd-
dc.titleEnhancing indoor building occupant safety in the built environment: Assessing the validity of social force modeling for simulating physical distancing behaviors-
dc.typeArticle-
dc.publisher.location네델란드-
dc.identifier.doi10.1016/j.dibe.2024.100336-
dc.identifier.scopusid2-s2.0-85183454461-
dc.identifier.wosid001175582500001-
dc.identifier.bibliographicCitationDevelopments in the Built Environment, v.17-
dc.citation.titleDevelopments in the Built Environment-
dc.citation.volume17-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaConstruction & Building Technology-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalWebOfScienceCategoryConstruction & Building Technology-
dc.relation.journalWebOfScienceCategoryEngineering, Civil-
dc.subject.keywordAuthorCOVID-19-
dc.subject.keywordAuthorFacility management-
dc.subject.keywordAuthorIndoor safety-
dc.subject.keywordAuthorPedestrian modeling-
dc.subject.keywordAuthorSafety measures-
dc.subject.keywordAuthorSocial force model-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Civil and Environmental Engineering > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ahn, Seung Jun photo

Ahn, Seung Jun
Engineering (Civil and Environmental Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE