A metal artifact reduction algorithm in CT using multiple prior images by recursive active contour segmentation
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Nam, Haewon | - |
dc.contributor.author | Baek, Jongduk | - |
dc.date.available | 2020-07-10T05:02:05Z | - |
dc.date.created | 2020-07-06 | - |
dc.date.issued | 2017-06-12 | - |
dc.identifier.issn | 1932-6203 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hongik/handle/2020.sw.hongik/5639 | - |
dc.description.abstract | We propose a novel metal artifact reduction (MAR) algorithm for CT images that completes a corrupted sinogram along the metal trace region. When metal implants are located inside a field of view, they create a barrier to the transmitted X-ray beam due to the high attenuation of metals, which significantly degrades the image quality. To fill in the metal trace region efficiently, the proposed algorithm uses multiple prior images with residual error compensation in sinogram space. Multiple prior images are generated by applying a recursive active contour (RAC) segmentation algorithm to the pre-corrected image acquired by MAR with linear interpolation, where the number of prior image is controlled by RAC depending on the object complexity. A sinogram basis is then acquired by forward projection of the prior images. The metal trace region of the original sinogram is replaced by the linearly combined sinogram of the prior images. Then, the additional correction in the metal trace region is performed to compensate the residual errors occurred by non-ideal data acquisition condition. The performance of the proposed MAR algorithm is compared with MAR with linear interpolation and the normalized MAR algorithm using simulated and experimental data. The results show that the proposed algorithm outperforms other MAR algorithms, especially when the object is complex with multiple bone objects. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | PUBLIC LIBRARY SCIENCE | - |
dc.subject | CONE-BEAM CT | - |
dc.subject | COMPUTED-TOMOGRAPHY | - |
dc.subject | PROJECTION DATA | - |
dc.subject | DENTAL CT | - |
dc.subject | RECONSTRUCTION | - |
dc.subject | SUPPRESSION | - |
dc.title | A metal artifact reduction algorithm in CT using multiple prior images by recursive active contour segmentation | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Nam, Haewon | - |
dc.identifier.doi | 10.1371/journal.pone.0179022 | - |
dc.identifier.scopusid | 2-s2.0-85020744395 | - |
dc.identifier.wosid | 000403088400026 | - |
dc.identifier.bibliographicCitation | PLOS ONE, v.12, no.6 | - |
dc.relation.isPartOf | PLOS ONE | - |
dc.citation.title | PLOS ONE | - |
dc.citation.volume | 12 | - |
dc.citation.number | 6 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Science & Technology - Other Topics | - |
dc.relation.journalWebOfScienceCategory | Multidisciplinary Sciences | - |
dc.subject.keywordPlus | CONE-BEAM CT | - |
dc.subject.keywordPlus | COMPUTED-TOMOGRAPHY | - |
dc.subject.keywordPlus | PROJECTION DATA | - |
dc.subject.keywordPlus | DENTAL CT | - |
dc.subject.keywordPlus | RECONSTRUCTION | - |
dc.subject.keywordPlus | SUPPRESSION | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
94, Wausan-ro, Mapo-gu, Seoul, 04066, Korea02-320-1314
COPYRIGHT 2020 HONGIK UNIVERSITY. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.