Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

펄트루젼 유리섬유-폴리에스터 복합재 판의 좌굴에 대한 안전율 평가Evaluation of Safety Factor on the Buckling of Pultruded Glass Fiber Reinforced Polyester Composite Plate

Other Titles
Evaluation of Safety Factor on the Buckling of Pultruded Glass Fiber Reinforced Polyester Composite Plate
Authors
유종호윤순종
Issue Date
2017
Publisher
한국복합신소재구조학회
Keywords
PFRP; orthotropic; plate buckling analysis; buckling strength; geometric mean; 펄트루젼 섬유보강 복합재; 직교이방성; 판의 좌굴해석; 좌굴강도; 기하평균
Citation
한국복합신소재구조학회 논문집, v.8, no.3, pp.30 - 36
Journal Title
한국복합신소재구조학회 논문집
Volume
8
Number
3
Start Page
30
End Page
36
URI
https://scholarworks.bwise.kr/hongik/handle/2020.sw.hongik/6407
DOI
10.11004/kosacs.2017.8.3.030
ISSN
2093-5145
Abstract
The pultruded fiber reinforced polymer plastic (PFRP) is one of the most actively studied composite materials for the structural member in construction industries. In domestic design process, the PFRP member is designed as an isotropic material having only longitudinal material properties for simplicity, because it is too complex to consider orthotrophy of PFRP perfectly. In this study, three cases of buckling analysis of PFRP plate is conducted theoretically and numerically. First, the PFRP plate is considered as an orthotropic material. Second, the PFRP plate is considered as an isotropic plate having only longitudinal material properties. Third, the PFRP plate is considered as an isotropic plate having geometric mean of longitudinal and transverse material properties. As a result of buckling analysis, a buckling strength of PFRP plate as an isotropic plate having only longitudinal material properties is about 2.21 times larger than that of PFRP plate analyzed as an orthotropic plate. On the other hand, a buckling strength of PFRP plate as an isotropic plate having geometric mean material properties is about 1.19 times larger than that of PFRP plate analyzed as an orthotropic plate. In conclusion, the safety factor of 3 used in domestic design process of PFRP member is no longer applicable due to overestimation of buckling strength of PFRP member which leads to nonconservative design.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Civil Engineering Major > 1. Journal Articles