Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

고무보 저층수 배출관의 유사 배제 성능 실험 연구

Full metadata record
DC Field Value Language
dc.contributor.author정석일-
dc.contributor.author이승오-
dc.date.available2020-07-10T06:22:05Z-
dc.date.created2020-07-06-
dc.date.issued2016-
dc.identifier.issn1738-3803-
dc.identifier.urihttps://scholarworks.bwise.kr/hongik/handle/2020.sw.hongik/8378-
dc.description.abstractMost small weir installed in Korea is concrete solidated weir. Fixed weir causes stagnant flow, which leads to deposit sediment just upstream of weir. As time goes on, it would induce reduction of water storage capacity and invoke the serious water quality issues. Therefore, there has been a growing interest in movable weir. Especially, the flexible rubber weir is easy to install and possible to operate in extreme environments. However, even though this type can be flatable, it is also not free from sediment deposition problem. Thus, to enhance the ability of releasing deposition the bypass pipe was constructed underneath it. In this study the performance of its ability was examined with hydraulic model test. This bypass pipe was designed with 3 different dimensions to connect between each bottom of upstream and downstream of a weir, such as Type A, B, and C. The efficiency of drainage of deposition upstream was studied under two water of upstream and sediment heights. In addition, the ability of sediment emission through the bypass pipe after the pipe was blocked by debris like soil, vegetation et al. was examined by video monitoring. From this study, it was suggested a dimensionless equation which show the relationship of variable parameters and amount of emission sediment through bypass pipe. And it was found that the most significant factors on efficiency of releasing were elbow angle and discharge, and the ability of emission when the pipe was blocked was most highly influenced in tilting length.-
dc.language한국어-
dc.language.isoko-
dc.publisher한국안전학회-
dc.title고무보 저층수 배출관의 유사 배제 성능 실험 연구-
dc.title.alternativeExperimental Study for Flushing of Sediment Bypass Pipe underneath Rubber Weir-
dc.typeArticle-
dc.contributor.affiliatedAuthor이승오-
dc.identifier.bibliographicCitation한국안전학회지, v.31, no.5, pp.133 - 140-
dc.relation.isPartOf한국안전학회지-
dc.citation.title한국안전학회지-
dc.citation.volume31-
dc.citation.number5-
dc.citation.startPage133-
dc.citation.endPage140-
dc.type.rimsART-
dc.identifier.kciidART002160606-
dc.description.journalClass2-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorbypass pipe-
dc.subject.keywordAuthoremission sediment-
dc.subject.keywordAuthorrubber weir-
dc.subject.keywordAuthorhydraulic experiments-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Civil Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Seung Oh photo

Lee, Seung Oh
Engineering (Civil and Environmental Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE