Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

급·배기 일체형 디퓨저의 환기 및 온열환경 유지성능에 대한 연구

Full metadata record
DC Field Value Language
dc.contributor.author임석영-
dc.contributor.author장현재-
dc.date.available2020-07-10T06:26:23Z-
dc.date.created2020-07-06-
dc.date.issued2016-
dc.identifier.issn1229-6422-
dc.identifier.urihttps://scholarworks.bwise.kr/hongik/handle/2020.sw.hongik/8575-
dc.description.abstractInstalling a ventilator for an apartment house composed of over 100 dwelling units was mandated in 2006 to improve indoor air quality. In the case of mechanical ventilators, the air change rate is kept stable, however 68% of dwellers do not operate their ventilator because of an increased electrical bill and noise. In the case of natural ventilators, the former problems are settled, but there are concerns about cold draught and an increase of heating/cooling cost. Authors are developing a heat recovery type natural ventilator which is a natural ventilator equipped with total heat recovery element, and it is expected that those problems of mechanical ventilator and natural ventilator are resolved by this. The combined type diffuser of this study is an under developed fit to the heat recovery type natural ventilator above. There are no standards to evaluate the performance for this type of diffuser. Due to this issue this study investigated the performance of the ventilation and maintained a thermal environment for the combined type diffuser by comparing it with existing diffusers. The results revealed that the performances of the combined type of diffusers showed different features from the existing ones, and was estimated to be high enough in the performances above.-
dc.language한국어-
dc.language.isoko-
dc.publisher대한설비공학회-
dc.title급·배기 일체형 디퓨저의 환기 및 온열환경 유지성능에 대한 연구-
dc.title.alternativeA Study on The Performance of Ventilation and Maintaining Thermal Environment for a Combined Type Diffuser-
dc.typeArticle-
dc.contributor.affiliatedAuthor장현재-
dc.identifier.doi10.6110/KJACR.2016.28.6.232-
dc.identifier.bibliographicCitation설비공학 논문집, v.28, no.6, pp.232 - 241-
dc.relation.isPartOf설비공학 논문집-
dc.citation.title설비공학 논문집-
dc.citation.volume28-
dc.citation.number6-
dc.citation.startPage232-
dc.citation.endPage241-
dc.type.rimsART-
dc.identifier.kciidART002113492-
dc.description.journalClass2-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorCombined type diffuser of supply and exhaust(급․배기 일체형 디퓨저)-
dc.subject.keywordAuthorHeat recovery type natural ventilator(폐열회수형 자연환기설비)-
dc.subject.keywordAuthorEffective draft temperature(유효드래프트 온도)-
dc.subject.keywordAuthorADPI(공기 확산 성능지표)-
dc.subject.keywordAuthorAge of air(공기령)-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Science and Technology > Major in Architecture Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chang, Hyun jae photo

Chang, Hyun jae
Science & Technology (Architectural Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE