Detailed Information

Cited 7 time in webofscience Cited 8 time in scopus
Metadata Downloads

Numerical study on the effect of initial flow velocity on liquid film thickness of accelerated slug flow in a micro tube

Authors
Muramatsu, KenshiroYoun, YoungjikHan, YoungbaeHasegawa, YosukeShikazono, Naoki
Issue Date
Aug-2015
Publisher
ELSEVIER SCIENCE INC
Keywords
Two-phase flow; Liquid film thickness; Micro tube; Acceleration; Phase-Field method
Citation
INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, v.54, pp.77 - 86
Journal Title
INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW
Volume
54
Start Page
77
End Page
86
URI
https://scholarworks.bwise.kr/hongik/handle/2020.sw.hongik/9602
DOI
10.1016/j.ijheatfluidflow.2015.04.005
ISSN
0142-727X
Abstract
Numerical simulation of air-water slug flows accelerated from steady states with different initial velocities in a micro tube is conducted. It is shown that the liquid film formed between the gas bubble and the wall in an accelerated flow is significantly thinner than that in a steady flow at the same instantaneous capillary number. Specifically, the liquid film thickness is kept almost unchanged just after the onset of acceleration, and then gradually increases and eventually converges to that of an accelerated flow from zero initial velocity. Due to the flow acceleration, the Stokes layer is generated from the wall, and the instant velocity profile can be given by superposition of the Stokes layer and the initial parabolic velocity profile of a steady flow. It is found that the velocity profile inside a liquid slug away from the bubble can be well predicted by the analytical solution of a single-phase flow with acceleration. The change of the velocity profile in an accelerated flow changes the balance between the inertia, surface tension and viscous forces around the meniscus region, and thus the resultant liquid film thickness. By introducing the displacement thickness, the existing correlation for liquid film thickness in a steady flow (Han and Shikazono, 2009) is extended so that it can be applied to a flow with acceleration from an arbitrary initial velocity. It is demonstrated that the proposed correlation can predict liquid film thickness at Re <4600 within the range of +/- 10% accuracy. (C) 2015 Elsevier Inc. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Science and Technology > Department of Mechanical and Design Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE