Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

G-quadruplex-filtered selective ion-to-ion current amplification for non-invasive ion monitoring in real time.

Full metadata record
DC Field Value Language
dc.contributor.authorYoo, Hyebin-
dc.contributor.authorLee, Hyun-Ro-
dc.contributor.authorKang, Soon-Bo-
dc.contributor.authorLee, Juhwa-
dc.contributor.authorPark, Kunwoong-
dc.contributor.authorYoo, Hyunjae-
dc.contributor.authorKim, Jinmin-
dc.contributor.authorChung, Taek Dong-
dc.contributor.authorLee, Kyung-Mi-
dc.contributor.authorLim, Hyun-Ho-
dc.contributor.authorSon, Chang Yun-
dc.contributor.authorSun, Jeong-Yun-
dc.contributor.authorOh, Seung Soo-
dc.date.accessioned2023-08-16T09:28:47Z-
dc.date.available2023-08-16T09:28:47Z-
dc.date.created2023-08-11-
dc.date.issued2023-09-
dc.identifier.issn0935-9648-
dc.identifier.urihttp://scholarworks.bwise.kr/kbri/handle/2023.sw.kbri/111-
dc.description.abstractLiving cells efflux intracellular ions for maintaining cellular life, so intravital measurements of specific ion signals are of significant importance for studying cellular functions and pharmacokinetics. In this work, de novo synthesis of artificial K+ -selective membrane and its integration with polyelectrolyte hydrogel-based open-junction ionic diode (OJID) is demonstrated, achieving a real-time K+ -selective ion-to-ion current amplification in complex bioenvironments. By mimicking biological K+ channels and nerve impulse transmitters, in-line K+ -binding G-quartets are introduced across freestanding lipid bilayers by G-specific hexylation of monolithic G-quadruplex, and the pre-filtered K+ flow is directly converted to amplified ionic currents by the OJID with a fast response time at 100 ms intervals. By the synergistic combination of charge repulsion, sieving, and ion recognition, the synthetic membrane allows K+ transport exclusively without water leakage; it is 250 and 17 times more permeable towards K+ than monovalent anion, Cl- , and polyatomic cation, N-methyl-D-glucamine+ , respectively. The molecular recognition-mediated ion channeling provides a 500% larger signal for K+ as compared to Li+ (0.6 times smaller than K+ ) despite the same valence. Using the miniaturized device, non-invasive, direct, and real-time K+ efflux monitoring from living cell spheroids is achieved with minimal crosstalk, specifically in identifying osmotic shock-induced necrosis and drug-antidote dynamics. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.-
dc.language영어-
dc.language.isoen-
dc.publisherWILEY-VCH Verlag GmbH & Co. KGaA, Weinheim-
dc.titleG-quadruplex-filtered selective ion-to-ion current amplification for non-invasive ion monitoring in real time.-
dc.typeArticle-
dc.contributor.affiliatedAuthorPark, Kunwoong-
dc.contributor.affiliatedAuthorLim, Hyun-Ho-
dc.identifier.doi10.1002/adma.202303655-
dc.identifier.wosid001065905500001-
dc.identifier.bibliographicCitationAdvanced Materials, pp.e2303655-
dc.relation.isPartOfAdvanced Materials-
dc.citation.titleAdvanced Materials-
dc.citation.startPagee2303655-
dc.type.rimsART-
dc.type.docTypeArticle; Early Access-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalResearchAreaMaterials Science-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryChemistry, Multidisciplinary-
dc.relation.journalWebOfScienceCategoryChemistry, Physical-
dc.relation.journalWebOfScienceCategoryNanoscience & Nanotechnology-
dc.relation.journalWebOfScienceCategoryMaterials Science, Multidisciplinary-
dc.relation.journalWebOfScienceCategoryPhysics, Applied-
dc.relation.journalWebOfScienceCategoryPhysics, Condensed Matter-
dc.subject.keywordPlusBARIUM PERMEATION-
dc.subject.keywordPlusHIGH-RESOLUTION-
dc.subject.keywordPlusPOTASSIUM-
dc.subject.keywordPlusAPTAMER-
dc.subject.keywordPlusCALCIUM-
dc.subject.keywordPlusEFFLUX-
dc.subject.keywordPlusFIELD-
dc.subject.keywordPlusAPOPTOSIS-
dc.subject.keywordPlusCHANNELS-
dc.subject.keywordPlusGUI-
dc.subject.keywordAuthorG-quadruplex-
dc.subject.keywordAuthorartificial ion channel-
dc.subject.keywordAuthorbiosensor-
dc.subject.keywordAuthorhydrogel ionic device-
dc.subject.keywordAuthorproteomimetics-
Files in This Item
There are no files associated with this item.
Appears in
Collections
연구본부 > 신경·혈관 단위체 연구그룹 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lim, Hyun-Ho photo

Lim, Hyun-Ho
연구본부 (신경·혈관단위체 연구그룹)
Read more

Altmetrics

Total Views & Downloads

BROWSE