G-quadruplex-filtered selective ion-to-ion current amplification for non-invasive ion monitoring in real time.
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Yoo, Hyebin | - |
dc.contributor.author | Lee, Hyun-Ro | - |
dc.contributor.author | Kang, Soon-Bo | - |
dc.contributor.author | Lee, Juhwa | - |
dc.contributor.author | Park, Kunwoong | - |
dc.contributor.author | Yoo, Hyunjae | - |
dc.contributor.author | Kim, Jinmin | - |
dc.contributor.author | Chung, Taek Dong | - |
dc.contributor.author | Lee, Kyung-Mi | - |
dc.contributor.author | Lim, Hyun-Ho | - |
dc.contributor.author | Son, Chang Yun | - |
dc.contributor.author | Sun, Jeong-Yun | - |
dc.contributor.author | Oh, Seung Soo | - |
dc.date.accessioned | 2023-08-16T09:28:47Z | - |
dc.date.available | 2023-08-16T09:28:47Z | - |
dc.date.created | 2023-08-11 | - |
dc.date.issued | 2023-09 | - |
dc.identifier.issn | 0935-9648 | - |
dc.identifier.uri | http://scholarworks.bwise.kr/kbri/handle/2023.sw.kbri/111 | - |
dc.description.abstract | Living cells efflux intracellular ions for maintaining cellular life, so intravital measurements of specific ion signals are of significant importance for studying cellular functions and pharmacokinetics. In this work, de novo synthesis of artificial K+ -selective membrane and its integration with polyelectrolyte hydrogel-based open-junction ionic diode (OJID) is demonstrated, achieving a real-time K+ -selective ion-to-ion current amplification in complex bioenvironments. By mimicking biological K+ channels and nerve impulse transmitters, in-line K+ -binding G-quartets are introduced across freestanding lipid bilayers by G-specific hexylation of monolithic G-quadruplex, and the pre-filtered K+ flow is directly converted to amplified ionic currents by the OJID with a fast response time at 100 ms intervals. By the synergistic combination of charge repulsion, sieving, and ion recognition, the synthetic membrane allows K+ transport exclusively without water leakage; it is 250 and 17 times more permeable towards K+ than monovalent anion, Cl- , and polyatomic cation, N-methyl-D-glucamine+ , respectively. The molecular recognition-mediated ion channeling provides a 500% larger signal for K+ as compared to Li+ (0.6 times smaller than K+ ) despite the same valence. Using the miniaturized device, non-invasive, direct, and real-time K+ efflux monitoring from living cell spheroids is achieved with minimal crosstalk, specifically in identifying osmotic shock-induced necrosis and drug-antidote dynamics. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim | - |
dc.title | G-quadruplex-filtered selective ion-to-ion current amplification for non-invasive ion monitoring in real time. | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Park, Kunwoong | - |
dc.contributor.affiliatedAuthor | Lim, Hyun-Ho | - |
dc.identifier.doi | 10.1002/adma.202303655 | - |
dc.identifier.wosid | 001065905500001 | - |
dc.identifier.bibliographicCitation | Advanced Materials, pp.e2303655 | - |
dc.relation.isPartOf | Advanced Materials | - |
dc.citation.title | Advanced Materials | - |
dc.citation.startPage | e2303655 | - |
dc.type.rims | ART | - |
dc.type.docType | Article; Early Access | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalResearchArea | Science & Technology - Other Topics | - |
dc.relation.journalResearchArea | Materials Science | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Multidisciplinary | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Physical | - |
dc.relation.journalWebOfScienceCategory | Nanoscience & Nanotechnology | - |
dc.relation.journalWebOfScienceCategory | Materials Science, Multidisciplinary | - |
dc.relation.journalWebOfScienceCategory | Physics, Applied | - |
dc.relation.journalWebOfScienceCategory | Physics, Condensed Matter | - |
dc.subject.keywordPlus | BARIUM PERMEATION | - |
dc.subject.keywordPlus | HIGH-RESOLUTION | - |
dc.subject.keywordPlus | POTASSIUM | - |
dc.subject.keywordPlus | APTAMER | - |
dc.subject.keywordPlus | CALCIUM | - |
dc.subject.keywordPlus | EFFLUX | - |
dc.subject.keywordPlus | FIELD | - |
dc.subject.keywordPlus | APOPTOSIS | - |
dc.subject.keywordPlus | CHANNELS | - |
dc.subject.keywordPlus | GUI | - |
dc.subject.keywordAuthor | G-quadruplex | - |
dc.subject.keywordAuthor | artificial ion channel | - |
dc.subject.keywordAuthor | biosensor | - |
dc.subject.keywordAuthor | hydrogel ionic device | - |
dc.subject.keywordAuthor | proteomimetics | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
61, Cheomdan-ro, Dong-gu, Daegu, Republic of Korea , 41062 053-980-8114
COPYRIGHT Korea Brain Research Institute. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.