Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

ICoRD: iterative correlation-based ROI detection method for the extraction of neural signals in calcium imaging

Full metadata record
DC Field Value Language
dc.contributor.authorKang, Seongtak-
dc.contributor.authorPark, Jiho-
dc.contributor.authorKim, Kyungsoo-
dc.contributor.authorLim, Sung-Ho-
dc.contributor.authorKim, Samhwan-
dc.contributor.authorChoi, Joon Ho-
dc.contributor.authorRah, Jong-Cheol-
dc.contributor.authorChoi, Ji-Woong-
dc.date.accessioned2023-08-16T09:30:11Z-
dc.date.available2023-08-16T09:30:11Z-
dc.date.created2022-09-02-
dc.date.issued2022-08-
dc.identifier.issn1741-2560-
dc.identifier.urihttp://scholarworks.bwise.kr/kbri/handle/2023.sw.kbri/209-
dc.description.abstractObjective. In vivo calcium imaging is a standard neuroimaging technique that allows selective observation of target neuronal activities. In calcium imaging, neuron activation signals provide key information for the investigation of neural circuits. For efficient extraction of the calcium signals of neurons, selective detection of the region of interest (ROI) pixels corresponding to the active subcellular region of the target neuron is essential. However, current ROI detection methods for calcium imaging data exhibit a relatively low signal extraction performance from neurons with a low signal-to-noise power ratio (SNR). This is problematic because a low SNR is unavoidable in many biological experiments. Approach. Therefore, we propose an iterative correlation-based ROI detection (ICoRD) method that robustly extracts the calcium signal of the target neuron from a calcium imaging series with severe noise. Main results. ICoRD extracts calcium signals closer to the ground-truth calcium signal than the conventional method from simulated calcium imaging data in all low SNR ranges. Additionally, this study confirmed that ICoRD robustly extracts activation signals against noise, even within in vivo environments. Significance. ICoRD showed reliable detection from neurons with a low SNR and sparse activation, which were not detected by conventional methods. ICoRD will facilitate our understanding of neural circuit activity by providing significantly improved ROI detection in noisy images.-
dc.language영어-
dc.language.isoen-
dc.publisherInstitute of Physics Publishing-
dc.titleICoRD: iterative correlation-based ROI detection method for the extraction of neural signals in calcium imaging-
dc.typeArticle-
dc.contributor.affiliatedAuthorChoi, Joon Ho-
dc.contributor.affiliatedAuthorRah, Jong-Cheol-
dc.identifier.doi10.1088/1741-2552/ac84aa-
dc.identifier.scopusid2-s2.0-85136043577-
dc.identifier.wosid000839306400001-
dc.identifier.bibliographicCitationJournal of Neural Engineering, v.19, no.4-
dc.relation.isPartOfJournal of Neural Engineering-
dc.citation.titleJournal of Neural Engineering-
dc.citation.volume19-
dc.citation.number4-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaNeurosciences & Neurology-
dc.relation.journalWebOfScienceCategoryEngineering, Biomedical-
dc.relation.journalWebOfScienceCategoryNeurosciences-
dc.subject.keywordPlusINDICATORS-
dc.subject.keywordAuthorsignal-to-noise power ratio-
dc.subject.keywordAuthorregion of interest-
dc.subject.keywordAuthorcalcium imaging-
dc.subject.keywordAuthordenoising-
Files in This Item
There are no files associated with this item.
Appears in
Collections
연구본부 > 감각·운동시스템 연구그룹 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Rah, Jong-Cheol photo

Rah, Jong-Cheol
연구본부 (감각·운동시스템 연구그룹)
Read more

Altmetrics

Total Views & Downloads

BROWSE